By default, the print, export and zoom buttons are displayed for the Operator in the Video surveillance monitor in the archive viewing mode.

You can hide these buttons. To do this:

  1. Go to the Users tab in the System settings dialog box.
  2. In the object tree located below the User permissions button, click on the object with the Operator permissions that you want to change.
    The User permissions object settings panel will be displayed in the right part of the window.
  3. Clear the Allow printing and saving of archive files checkbox.
  4. Click the Apply button.

Configuring the display of buttons for printing and saving archive files in the Video surveillance monitor is complete.

Note

User permissions take precedence over the HideArchSaveAndPrintButtons registry key which performs the same function (see Registry keys reference guide). Use the registry key if there are no users and permissions created in the System.

See also Permissions for export and printout, which control the ability to export via the camera menu in the Surveillance window.