Documentation for Axxon PSIM 2.0. Documentation for other versions of PSIM is available too.

Previous page Next page


The Control panel object is used to register and configure a specialized control panel used to manage the PTZ devices in Axxon PSIM.

The settings panel of the Control panel object is shown in the figure.

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Control panel object in the video surveillance system with the distributed architecture

Numbers, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Control panel objects in the video surveillance system with the distributed architecture

2

Name*

Enter the value in the field

Sets the name of the Control panel object in the video surveillance system with the distributed architecture

Latin, Cyrillic characters, and service characters

Control panel

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Disables the Control panel object in the video surveillance system with the distributed architecture

Boolean type

Clear

Setthe Control panel object is disabled and isn't used

Clearthe Control panel object is enabled and is used

4

Telemetry Controller

Select the value from the list

Sets the Telemetry Controller parent object of the system with the distributed architecture to which the given Control panel object belongs

Name of the Telemetry Controller objects registered in the system

Name of the Telemetry Controller parent object

Depends on the number of telemetry controllers in the video surveillance system with the distributed architecture

The Settings group

5

Port

Select the value from the list

Sets the number of the computer serial (COM) port used to connect the Control panel

List of available COM ports 

COM1

Depends on the number of COM ports on the server or Remote Administrator's workstation

6

Speed

Select the value from the list

Sets the data communication speed via the serial (COM) port

Kb/s


9600

From 300 to 256000

7

Parity

Select the value from the list

Sets the parity check mode for the data transmission over the serial (COM) port

List of the parity check modes

None

Even, Odd, None, Mark, Space

8

DTR

Set the checkbox

Disables the object

Boolean type

Set

Setthe power is supplied via the DTR port output

Clearthe power isn't supplied via the DTR port output

9

RTS

Set the checkbox

Disables the object

Boolean type

Set

Set—the power is supplied via the RTS port output

Clear—the power isn't supplied via RTS port output

10

Priority

Select the value from the list

Sets the priority for controlling the PTZ devices via the Control panel

Names of priorities used to control the PTZ devices

Low

  • Control prohibited—you cannot control the PTZ device using the Control panel;
  • Low—you can control the PTZ device after it is controlled by the devices with the standard or high priority;
  • Standard—you can control the PTZ device after it is controlled by the device with the high priority;
  • Highthe PTZ device is controlled first

*Name of the element isn't displayed in the settings panel of the given object.