The Security zone object is used for the general configuration of Axxon PSIM.

The settings panel of the Security zone object is shown in the figures with tabs. The tables describe the settings.

The Basic settings tab:

 

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Holidays 
field

You can add the dates by clicking the Add button

List of calendar days which are determined as holidays in Axxon PSIM

List of dates

NADate format: DD-MM-YY

2

The Add button

Click the button

Opens the Calendar window to select the date of a new holiday

NA

NA

NA

3

The Delete 
button

Click the button

Deletes the selected holiday date from the Holidays list

NA

NA

NA

4

The Edit button

Click the button

Opens the Calendar window to change the date of the selected holiday in the list

NA

NA

NA

5The Ping (s)
field
Enter the value in the field

Sets the check period for the computer connection to the server

Sequence of numbers10>=1
6The Default object access level
drop-down list
Select the value from the list

Sets the default object access level

List of access levels

Monitoring/
Control/
Configuration

  • No access;
  • Monitoring;
  • Monitoring/Control;
  • Monitoring/Control/
    Configuration
7The Default user rights
drop-down list
Select the value from the list

Sets the default user rights

List of user rights Full
  • Full. If you select this value, the created rights for system operation will be unlimited;
  • User rights. These rights are created on the Users tab.
    For more details, see Registration of operator rights
8The Debug statistics
button
Click the buttonOpens the window with the events queue statisticsNANANA
9The Synchronization
button
Click the buttonWhen you click the button, the system performs synchronization and applies configuration that was created on the computer where you clicked the buttonNANANA
10The Protocol clear time
field
Enter the value in the field using the up and down buttonsSets the time of the day at which you must start cleaning up the Event Viewer database according to the Events archive length parameterHH:MM:SSCurrent system time at the moment of opening the object settings panelFrom 00:00:00 to 23:59:59

11

The Events archive length days
field

Enter the value in the field

Sets the number of days to store information about the events registered by Axxon PSIM and recorded into both the Event Viewer and the Incident server. This parameter affects all computers in a distributed system

Days

3

From

12

The Object code
field

Enter the value in the field

Sets the number of the access control card, which is automatically displayed in the settings panel of the User object when the object is created in the Object code field

Sequence of numbers

NA

More than 1

13

The Starting configuration
drop-down list

Select the value from the list

Sets the macro, which runs automatically when starting Axxon PSIM 

Names of the Macro objects registered in the system

NA

Depends on the number of the Macro objects created in the video surveillance system with distributed architecture

14

The Connections in architecture
checkbox

Set the checkbox

Sets the computers with which the created Computer object must exchange the data about the system configuration parameters: with all computers in the video surveillance system with the distributed architecture or only with the Computer object on the basis of which the given object is created

Boolean type

Clear

Setwhen creating a new computer, the Connection checkboxes in the Architecture tab are set for all computers in the architecture

Clearwhen creating a new computer, the Connection checkbox in the Architecture tab is set only for the computer from which this new object is created

15

The DNS instead of IP allowed
checkbox

Set the checkbox

Sets the address of the server/Remote Administrator’s workstation/Remote Client on the Architecture tab as DNS name, not only IP address

Boolean type

Clear

Set—when you configure the interaction of computers in the distributed system, specify the DNS name of the server/Remote Administrator’s workstation/Remote Client instead of the IP address on the Architecture tab. At the same time, the verification of the specified address is disabled

Clear—when you configure the interaction of the computers in the distributed system on the Architecture tab, specify the IP address of the server/Remote Administrator’s workstation/Remote Client

16

The Disable synchronization
checkbox

Set the checkbox

Disables event synchronization

Boolean type

Clear

Setsynchronization is enabled. Events are sent right after they occur in accordance with the parameters of the distributed system's computer interaction settings

Clear—synchronization is disabled. Events aren't sent

17

The log operation of services
checkbox

Set the checkbox

Enables service log operation

Boolean type

Clear

Set—service log operation is enabled

Clear—service log operation is disabled

18The Show documentation by clicking F1
checkbox
Set the checkboxEnables opening documentation in the pdf format by pressing the F1 button when Axxon PSIM is running. The Administrator's Guide section is opened on the server and the Remote Administrator's workstation; the Operator's Guide section is opened on the Remote ClientBoolean typeClear

Setdocumentation is displayed by pressing the F1 button

Clear—the feature of displaying documentation by pressing the F1 button is disabled

19The Shutdown with administrator password
checkbox
Set the checkboxEnables the shutdown by the administrator passwordBoolean typeClear

Set—the feature of shutdown by the administrator password is enabled

Clear—the feature of shutdown by the administrator password is disabled

20The Administrator’s password
button
Click the buttonOpens the Set password window for setting or changing the administrator passwordNANANA

The Date and time format tab

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1The Date format
drop-down list
Select the value from the list

Sets the format of the date that is displayed in the Incident manager, Operator protocol, and the Video surveillance monitor in the current date field when you work with the archive

  • Current;
  • dd/MM/yy;
  • MM/dd/yy;
  • yyyy-MM-dd
Current
  • Current—the date format set in the OS;
  • dd/MM/yy—the day/month/year format;
  • MM/dd/yy—the month/day/year format;
  • yyyy-MM-dd—the year/month/day format
2The Time format
drop-down list
Select the value from the listSets the format of the time that is displayed in the Incident manager, Operator protocol, and the Video surveillance monitor in the current date field when you work with the archive
  • Current;
  • HH:mm:ss;
  • hh:mm:ss tt
Current
  • Current—the time format set in the OS;
  • HH:mm:ss24-hour format;
  • hh:mm:ss tt12-hour format
3The NTP synchronization
checkbox
Set the checkboxEnables NTP synchronizationBoolean typeClear

Set—NTP synchronization is enabled

Clear—NTP synchronization is disabled

4The NTP server address
field
Enter the value in the field

Sets the address of the NTP server.

Note. The field becomes active after you set the NTP synchronization checkbox

NANANA 

The RabbitMQ tab

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1The Server
field
Enter the value in the fieldSets the RabbitMQ server addressLatin alphabet, numbers, and service characterslocalhostserver IP address or name
2

The Port
field


Enter the value in the fieldSets the RabbitMQ server portInteger numbersNA

065535.

If the port is 0 or not specified, RabbitMQ won't run

3The User
field
Enter the value in the fieldSets the RabbitMQ server usernameLatin alphabet, numbers, and service charactersguestDepends on the registered RabbitMQ users
4The Password
field
Enter the value in the fieldSets the RabbitMQ server user passwordLatin alphabet, numbers, and service charactersguestDepends on the registered RabbitMQ users
5

The Content-type
drop-down list

Select the value from the listSets the type of the sent/received contentAvailable types of contentEmpty line

application/json—a message in JSON format is sent

plain/textThe Axxon PSIM event is sent in the "TYPE|ID|EVENT" format

The Password policy tab

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1The User password policy
checkbox
Set the checkboxChanges the user password settingsBoolean typeClear

Set—you can change the user password settings

Clear—you cannot change the user password settings

The User password policy table*

Note. The User password policy table* is active only after you set the User password policy
checkbox

2The Password length
field
Enter the value in the fieldSets the password lengthSequence of numbers8>0
The Small letters
drop-down list
Select the value from the listUses small letters when creating a passwordBoolean typeOK

OK—you can use small letters

No—you cannot use small letters

The Capital letters
drop-down list
Select the value from the listUses capital letters when creating a passwordBoolean typeOK

OK—you can use capital letters

No—you cannot use capital letters

The User numbers
drop-down list
Select the value from the listUses numbers when creating a passwordBoolean typeOK

OK—you can use numbers

No—you cannot use numbers

The Characters
drop-down list
Select the value from the listUses characters when creating a passwordBoolean typeOK

OK—you can use characters

No—you cannot use characters

*Name of the element isn't displayed in the settings panel of the given object