Documentation for Face PSIM 2.0.

Previous page Next page

Configure the Face Detection module operation with a thermal camera or an external system as follows:

  1. Go to the External source tab (1) on the settings panel of the Face Detection object.
  2. From the Combined work drop-down list (2), select the combined operation mode:

    • Nocombined operation mode is not used;

    • Combine with thermal camera temperaturereceiving the temperature and coordinates of a captured face frame from the thermal camera. A photo of a captured face will be obtained from the capturing camera. If this mode is selected, the following setting become available.

  3. Thermal camera reply timeout (3)sets the timeout in seconds for receiving data from the thermal camera;

    Note

    The FIND_PERSON event will be generated only when the temperature is received from the thermal camera or after the time specified in the Thermal camera reply timeout parameter.

    • Get photo from thermal camerareceiving the temperature and photos of a captured face from the thermal camera;

    • Get photo and metadata from external systemreceiving the temperature and photos of a captured face from a thermal camera or Axxon One.

  4. Click the Apply button (4) to save the changes.

  • No labels