All video cameras or archives stop working once the license maximum is reached

If the activation key allows the use of a smaller number of video cameras than the amount used at the moment on the system, all of the video cameras will cease to function with the system. To resume operation, remove the objects corresponding to the excess number of video cameras and restart the server.

Note

Restart the Server through the Start menu as follows:

  1. All Programs -> Axxon Next -> Shut Down Server
  2. All Programs -> Axxon Next -> Start Server

Similarly, if an activation key allows using archives with a total size of an amount less than the current one, you are advised to correct the archive size to the required amount and then restart the server.

Error creating new archives even when license restriction on total size is observed

If the user creates archives at the same time (in other words, without applying changes) while deleting some existing archives, creation of archives may be forbidden even if the total archive size does not exceed the amount of the license restriction.

Note

This happens because when verifying the license restrictions, the size of created archives is calculated based on the total size the last time when changes were applied

To regain the ability to create new archives in such situations, the user must first delete unnecessary archives and apply changes.

Error creating archives larger than 2 TB

At present, Axxon Next may experience difficulties when trying to create an archive larger than 2 TB on a system that has a large number of video cameras (more than 20).

If you encounter such an error, you are advised to split the logical disk into multiple partitions that are less than 2 TB each and to place the archive on them.

Performance of Axxon Next when working with NetLimiter 2

If NetLimiter 2 is installed in the system, there may be a significantly increased load on the processor when working with Axxon Next.