The declared recognition quality is guaranteed if the cameras are installed at angles of not more than 20 degrees to the perpendicular to the plate. In case of larger angles (up to 45 degrees) the numbers will be recognized, although the recognition accuracy will decrease.
The following table shows the main parameters required for camera installation.
Parameter | Maximum value | Recommended (optimal) value |
---|---|---|
Camera height | 20 m | 6 m |
Vertical inclination | 30 º | 18 º |
Horizontal inclination | 20 º | 5-10 º |
Maximum inclination of the license plate | 10 º | 10 º |
Zone width of a CCTV camera:
Zone width of a 1 Mpix digital camera:
6.5 m – frontal location.
Zone width of a 3 Mpix digital camera:
6.5 m – frontal location.
By default, the cameras are installed at a height of 6 m above the controlled lane edge. The control zone center is located 20 m from the camera. The camera is tilted at an angle of18 degrees.
We recommend placing the cameras above the edge of the road, and not above the center. In this case, the horizontal inclination will amount to 4 degrees for the control zone width of 3 m.
By default, the cameras controlling the security site entrances and exits are located at a height of 3 m above the lane edge. The control zone center is then located 11 m from the camera.
After the camera is mounted, the lens focal length should be adjusted to the required viewing distance.
To set up the lens without the Uragan software, do the following:
To set up the camera, do the following:
Set the required shutter speed.
1/1000 sec is enough in most cases. |