The system supports use of four fixed sensors (vibration sensor, lock sensor, temperature sensor, and additional sensor) as well as 12 expansion sensors. There is also a separate additional device, "temperature array".
Before configuring a list of sensors for a protected site, you must create and configure the necessary Sensor objects in Intellect first. Creation and configuration of these objects is described in the document Installing and configuring security system components guide. |
Sensor IDs must be whole numbers. |
If video data (i.e. clips or snapshots) are attached to the alarms, it is necessary to create a script for stopping recording on camera (see Sample script for stopping camera recording). |
To configure the list of sensors in use:
To enable sending video frames to Server of Control when a sensor is activated, select the Transmit snapshots check box (5). In the Assignment to camera field, specify the camera from which you want video frames to be sent (4).
The settings for sending video frames and for sending video fragments are different. |
In the Interval (sec.) field, enter the length of time, in seconds, between video frames if more than one frame is to be sent (10). Thus when an alarm occurs, it is possible to send to Server of Control an entire sequence of frames that represent different points in time, which increases the chance of viewing the most valuable frames (for video frame transmission mode).
For snapshots transmitting more, as well as for video clips transmitting, it is necessary to create a script for stopping video recording on camera (see Sample script for stopping camera recording). |
When specifying the Pre-alarm time, Number of frames, and Interval settings, keep an eye on the configuration of the camera from which video frames are to be sent, and particularly on the Pre-Alarm record setting. Pre-Alarm record time on camera have to be greater or equal to Pre-Alarm time value in sensor settings. |
In the Length (sec.) field (1), specify the length of the video fragment to send (for video fragment transmission mode).
This setting is unavailable in the current version. The length will be determined by the size of the video fragment file in the video archive. To limit the length of the video fragment to be sent, use a script to stop recording on the camera (a sample script is found in the Sample script for stopping camera recording). |
Configuration of the list of used sensors is now complete.