Settings panel of the Monitoring interface object is given on figure ( Fig. 8.4—1).
Fig. 8.4—1 Settings panel of the Monitoringobject
Description of the Monitoring object settings panel elements is given in table (Tab. 8.4—1).
Tab. 8.4—1 Elements of settings panel of the Monitoring object
# |
Name |
Method for setting the parameter value |
Description |
Type |
Default value |
Value range |
---|---|---|---|---|---|---|
1 |
Identifier |
Automatically |
Shows the identification number of the Monitoring object in the system |
Nonnegative integer |
- |
>=0 |
2 |
Name |
Enter the value in the field |
Shows the name of the Monitoring object in the system |
Latin, Cyrillic letters and service characters |
Monitoring |
A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. |
3 |
Display |
Is selected in the list |
Assigns the parent Display object for the Monitoring object |
Names of Display objects registered in the system |
Name of the parent Display object |
Depends on the number of the Display objects in the system. |
4 |
Control panel |
Is set in a checkbox |
Enables Control panel displaying |
Boolean |
True |
True - Control panel is displayed |
5 |
X: |
Enter the value in the field |
Set the X coordinate in the horizontal axis for the upper-left corner of the Control panel interface box |
% of the screen width |
0 |
from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
6 |
Y: |
Enter the value in the field |
Set the Y coordinate in the vertical axis for the upper-left corner of the Control panel interface box |
% of the screen height |
50 |
from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
7 |
W: |
Enter the value in the field |
Set the width of the Control panel interface box |
% of the screen width |
100 |
from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
8 |
H: |
Enter the value in the field |
Set the height of the Control panel interface box |
% of the screen height |
50 |
from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
9 |
Log panel |
Is set in a checkbox |
Enables Log panel displaying |
Boolean |
True |
True - Log panel is displayed |
10 |
X: |
Enter the value in the field |
Set the X coordinate in the horizontal axis for the upper-left corner of the Log panel interface box |
% of the screen width |
0 |
from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
11 |
Y: |
Enter the value in the field |
Set the Y coordinate in the vertical axis for the upper-left corner of the Log panel interface box |
% of the screen height |
0 |
from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
12 |
W: |
Enter the value in the field |
Set the width of the Log panel interface box |
% of the screen width |
100 |
from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
13 |
H: |
Enter the value in the field |
Set the height of the Log panel interface box |
% of the screen width |
50 |
from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
14 |
Non-empty Comment field |
Is set in a checkbox |
Is set to require that operators leave comments when accepting an alarm to describe the alarm and/or their actions |
Boolean |
True |
True - Comment field shall not be empty on alarm accepting |
15 |
Warning when watching live video |
Is set in a checkbox |
Is set if when live video is attempted to be viewed from Control Panel it is necessary to display a warning that it can create the critical load per data channel |
Boolean |
True |
True - when live video is attempted to be viewed from Control Panel the warning is displayed |
16 |
Video stream speed |
Enter the value in the field |
Sets the frame rate for live video displaying |
Frames per second |
25 |
Depnds on the camera features |
17 |
Groups of alarms |
Is set in a checkbox |
Sets alarms that one want to visualize on the Control panel |
Boolean |
All checkboxes except the Temperature sensors are set |
If checkbox is set next to the group of alarms, then alarm from the corresponding group will be displayed on the Control panel |