Installation of Server of Control is performed in the following sequence:
A window appears, allowing you to configure the MonitorSSTV database. In the Name field, enter the name that will be used to refer to the database.
By default, the name of the database is "MonitorSSTV" and its files will be stored in the SQL Server folder. |
In the Data Link Properties window, select the name of the database server and specify connection settings. If a password is used, in the Allow saving password dialog box, select the check box.
In the 1. Select or enter a server name field specify the "127.0.0.1" value instead of computer name or "(local)" value, e.g. "127.0.0.1\SQLEXPRESS". Otherwise Server of Control will lose connection with its local database when the network cable is disconnected. |
If the parameters have been indicated correctly and the database server is functional, click the Test connection button, after which a message appears: Connection verified. Otherwise, an error message appears.
If the English version of MDAC components is installed on the computer, English is used in the dialog boxes as well. |
Installation of Server of Control is complete.