To configure a controller's EEPROM limits, go to the setup panel of the controller's object and click EEPROM Address assignments.

The EEPROM Address Assignmentswindow opens.

To configure the EEPROM limits:
- If you want to configure the EEPROM, select the EEPROM programmed checkbox (1).
- If the reset switch is enabled, select the Reset switch enabled checkbox (2).
- If the AC failure input is enabled, select the AC failure input enabled checkbox (3).
- If the tamper switch is enabled, select the Tamper switch enabled checkbox (4).
- If the battery failure input is enabled, select the Battery failure input enabled checkbox (5).
To set the limits for each of the above switches/inputs, go to the relevant parameter group.
Parameter | Description |
HRUL | High Range Upper Limit |
HRLL | High Range Lower Limit |
LRUL | Low Range Upper Limit |
LRLL | Low Range Lower Limit |
- In the AC failure input debounce time, msec field, enter the time period (in milliseconds) to be used for fixing (debouncing) the bouncing AC failure input signal (6).
- In the Tamper switch debounce time, msec field, enter the time period (in milliseconds) to be used for fixing (debouncing) the bouncing tamper switch signal (7).
- In the Battery failure debounce time, msec field, enter the time period (in milliseconds) to be used for fixing (debouncing) the bouncing battery failure input signal (8).
- Click OK to save the changes. This also brings you back to the setup panel (9).
To come back to the setup panel without saving the changes, click Cancel (10). |
The EEPROM limits are now configured.