Connection of BioSmart ACS controllers of all types is configured the same way.
BioSmart ACS controller is connected to ACFA Intellect as follows:
- Create the Computer (LOCALHOST)-based BioSmart2 object in the Hardware tab of the System settings dialog box. Each controller corresponds to the BioSmart2 object.

- Go to the settings panel of the BioSmart2 object.

- Select the controller connection type in the corresponding list (1).
- If connection is performed via RS-485 standard, then specify the COM port number and speed of its connection (2).
- If connection is performed via Ethernet standard, then specify IP address and controller port (3).
- Click the Apply button to save all changes.
- Create the Biosmart 4 or BioSmart PROX (BioSmart PROX v.2 controller corresponds to this object if connection is performed via RS-485 standard BioSmart PROX-E controller if connection is performed via Ethernet standard) controller object on the base of the BioSmart2 object.

- On the settings panel of the created object specify the serial number of controller BioSmart ACS.

- Click the Apply button.
Only one server (Intellect or Biosmart software) can be connected to a controller at a time. If some software has connected to the controller, other servers are not able to establish connection. |
BioSmart ACS controller is now connected to ACFA Intellect.