A system can include four fixed sensor types (vibration sensor, lock sensor, temperature sensor, extra sensor) as well as 12 extension sensors. There is another device as well, "Temperature sensor set".
Before configuring the sensors list, create and configure all required Sensor objects in the Intellect software. Connecting, creating and configuring of sensors are described in the document INTELLECT software package. Installing and configuring security system components guide. |
The ID numbers for these sensors must be whole integers. |
If video data (i.e. clips or snapshots) are attached to the alarms, it is necessary to create a script for stopping recording on camera (see Example of script to suspend recording on camera). |
To configure the list of used sensors, do the following:
Set the Transmit snapshots checkbox to send video frames to ATM Intellect Workstation when the sensor is activated, select this check box (5). In the Attach to camera field, indicate the video camera from which you want video frames to be sent (4).
Configuration parameters for video and snapshots transmitting are different. |
In the Interval (sec) field enter the interval, in seconds, between video frames if more than one frame is being transmitted (2). This means that when an alarm occurs, ATM Intellect Workstation can receive a whole series of frames that are dispersed over time, which increases the likelihood of getting a high-quality still-image frame (for Transmit snapshots mode).
For snapshots transmitting more, as well as for video clips transmitting, it is necessary to create a script for stopping video recording on camera (see Example of script to suspend recording on camera) |
When configuring the Pre-alarm time, Number of frames, and Interval settings, you are advised to keep in mind the configuration of the video camera from which the imagery will be sent (specifically, the Pre-alarm record setting).![]() |
In the Length (sec) field enter the length of the transmitted video fragment (for Transmit video mode).
This setting cannot be accessed in this version of the program (1). The length will be determined by the size of the video footage file in the video archive. To limit the length of the video fragment that is sent, pause camera recording by using a script (a sample script is given in Example of script to suspend recording on camera). |
Configuring the list of used sensors is completed.