Connect

Connect(BSTR ip, BSTR login, BSTR password, BSTR arch_password, long param, long param) set up a connection to the Server/Video Gate/Backup Archive.

The connection to Server is set up asynchronously.

If login and password are not specified at Connect() method call, all cameras are viewable in the control. It is to be considered when developing third-party application if access privileges are relevant.

 

ShowCam

ShowCam(long cam_id, long compress, long show) shows/hides camera on the monitor.

DoReactMonitor

DoReactMonitor(BSTR react_string) – control over the monitor/cameras

How to create react_string:

react_string =   "MONITOR||ARCH_FRAME_TIME|cam<3>,date<dd-mm-yy>,time<hh:mm:ss>";
CamMonitor1->DoReactMonitor(react_string);

The result of calling the function with the parameter: camera 3 will be in the archive mode and the archive will be positioned to date «dd-mm-yy» and time «hh:mm:ss» (date and time are to be set in this format only).

The mode parameter takes the following values:

0 – video gate if it's specified (otherwise, video server).

1 – video server.

2 – long-time archive.

“MONITOR|<id ignored>|ARCH_FRAME_TIME|...”

 Positioning accuracy can be specified in milliseconds, for instance:

DoReactMonitor(“MONITOR||ARCH_FRAME_TIME|cam<3>,date<02-10 05>,time<12:12:22.345>

Example. Show 2nd stream from camera 14 on Monitor 1:

"MONITOR|1|ADD_CAM|cam<14>,cam_id<14>,compress<1>,stream_id<14.2>"

RemoveAllCams

RemoveAllCams() : long – remove all cameras from the monitor

IsConnected

IsConnected() : boolean – method shows if the Video server is connected or disconnected.

GetCurIp

GetCurIp() : BSTR – returns the IP address of Server specified when calling Connect.

SendRawMessage

SendRawMessage(BSTR msg) – sends the command to be executed to Video server.

How to call a function:

m_Cam.SendRawMessage("CAM|1|REC");


m_Cam.SendRawMessage("CAM|1|REC_STOP");


m_Cam.SendRawMessage("CAM|1|ARM");


m_Cam.SendRawMessage("CAM|1|DISARM");

Disconnect

Disconnect() – disconnect from the Video server. 

SetCallBackOptions

SetCallBackOptions(int cam_id, int options) – sets parameters of getting video from camera.

The options parameter is created the same as parameters of the CamMonitor.ocx component – see CamMonitor.ocx parameters.

SetParam

SetParam(BSTR param_name, BSTR param_value) - sets the number of camera windows in CamMonitor.

How to call a function:

m_cam.SetParam("monitor_ch", m_NH);
m_cam.SetParam("monitor_cw", m_NW);