Intellect supports connecting devices via the Chinese standard GB/T28181. As of when this document was written, Intellect supports H.264 video and telemetry. For the most up-to-date information on this standard and the features supported in Intellect, see the Documentation Drivers Pack.
Configuration of IP devices connected via GB/T28181 is performed through the web interface of the devices. Settings are not sent from Intellect to the device. |
Before connecting a camera via this protocol to Intellect, perform the following steps to configure the device:
The name of this setting may vary on some cameras. |
For telemetry to work correctly, set RefreshRegTime to more than 600. |
For a camera to work correctly via GB/T28181, it must be on the same LAN as the Server. |
Intellect does not support auto-discovery of devices connected via GB/T28181 and these devices are not added using the Camera discovery tool. |
After configuring the device as described earlier, add it to Intellect as follows:
Further functioning of the device is performed using the created Camera object – see Configuring video subsystem section of Administrator's Guide.
A camera via GB/T28181 protocol is now added.