Technologically integration is a synchronization of information streams between software and FSA/ACS hardware. There are four main information streams between software and FSA/ACS hardware.
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT) | Connection interface (RS-232, TCP\IP) |
POLON ALPHA
| Polon4500, Polon4900, TSR, ROP, EKS, EWK, SAL, UCS | Monitoring | INTELLECT Alarm Service (Polon), per panel | Polon-Alfa Spółka z ograniczoną odpowiedzialnością Sp.k. http://www.polon-alfa.pl/en | low-level protocol | RS-232 |
Satel | INTEGRA 128, Satel CA64. | Monitoring | INTELLECT Alarm Service (Satel), per panel | SATEL www.satel.pl | low-level protocol | RS-232 |
Aritech | FP2000 | Monitoring, control | INTELLECT Alarm Service (Aritech), per panel | Aritech | low-level protocol | COM port |
UniPOS | IFS – 5000, 7000, 7203-O, 7203-IO, 7203-R, 7203-OC | Monitoring, configuration, control | UniPOS | low-level protocol | RS-232 | |
SALTO | CU50ENSVN, GateWay, Encoder | Monitoring, configuration, control | INTELLECT SALTO integration module | Salto www.saltosystems.com | SOFT-SOFT | IP |
TELSAP | Telsap 2100 | Monitoring, configuration, control | low-level protocol | RS-232 |
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT) | Connection interface (RS-232, TCP\IP) |
Honewell N-1000 (past | N-1000 | Monitoring, control | INTELLECT Access Control Service (Honeywell N-1000-IV), per COM port | Honeywell Systems Group Video and Access Control Solutions www.security.honeywell.com | low-level protocol | RS-232 |
Kronverk | Kronverk CM-T | Auto configuration, monitoring, configuration, control | Kronverk CM-T | "Access control systems" JSC www.kronwerk.ru | SDK | RS-232 - convertor - RS-485 |
Suprema | XPass X-Station BioEntry Plus SecureIO | Monitoring, control | Intellect Access Control Service (Suprema), per controller | Suprema www.supremainc.com | SDK | Ethernet |
KeyKing | TC312NT TC322NT TC344NT TC348NT TC388NT | Monitoring, configuration, control | KEYKING | low-level protocol | RS-232, RS-485, Ethernet | |
Paxton | Net2 nano Net2 plus Net2 classic | Monitoring, configuration, control | Paxton HouseHome Farm RoadBrightonBN1 9HUUnited Kingdom support@paxton.co.uk Skype: paxton.support | SOFT-SOFT | RS-232, USB, Ethernet | |
Pelco | eIDC Intelli-M | Monitoring, configuration, control | Infinias 9340 Priority Way West DriveIndianapolisIN 46240 USA sales@infinias.com support@infinias.com Main Number: 317.348.1086 Toll Free: 866.496.5783 Fax: 888.527.7506 | low-level protocol | Ethernet | |
Impro | Impro (ECII) Ethernet Controller Impro (iTRT) Intelligent Twin Reader Terminal Impro (iTT) Intelligent Twin Antenna Terminal Impro (MDTA) Multi-discipline Time Attendance Impro I16 16 Channel Input Terminal Impro O16 16 Channel Output Terminal | Impro Technologies | SOFT-SOFT | Ethernet, RS485 | ||
Anson DB | ||||||
Velocity Hirsch |
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT) | Connection interface (RS-232, TCP\IP) |
FSG | IPID Sterownik FSG | Monitoring, control | IPID Sp. z o.o. Tel.: 123 977 613 | BACnet protocol | Ethernet | |
Forteza | Zebra-30, Zebra-60, Zebra-100, Relief | Monitoring, auto configuration, configuration, control | "OKHRANNAYA TECHNIKA" LLC Tel.: +7 8412 655316 Fax: +7 8412 655316 E-mail: info@forteza-eu.com www.FORTEZA-EU.com | low-level protocol | RS-232 | |
Optex | REDSCAN RLS-3060SH RedBeam RBM-60QN/100QN/200QN IP | Monitoring, control | OPTEX CO., LTD. | low-level protocol | Ethernet | |
Intrepid I | PM, Micropoint cable, LU, NIM | Monitoring, control | Southwest Microwave, Inc. | SDK | RS-232 | |
Intrepid II | PM-II, MTP-II, AIM-8, AIM-16, ROM-8, ROM-16, MicroWave 330 | Monitoring, control | Southwest Microwave, Inc. 9055 South McKemy Street Tempe, Arizona 85284 USA Telephone: (480) 783-0201 Fax: (480) 783-0401 | low-level protocol | RS-232 |
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT) | Connection interface (RS-232, TCP\IP) |
Paradox | EVO48 ЕVO192 ACM12 | Monitoring, configuration, control | Paradox Security Systems Canada 780 Industrial BoulevardSt-Eustache, QuebecCanada, J7R 5V3 Tel: (450) 491-7444 Fax: (450) 491-2313 | low-level protocol | RS-232, USB | |
FoxSec | FS9000 FS7002PX (MK) FS7011PX (MK) | Monitoring, configuration, control | FoxSec | low-level protocol | Ethernet | |
ApolloSDK v.2 | AAN-100 AAN-32S AAN-32N AIM-2SL AIM-4SL AIO-168 ASA-72 | Monitoring, configuration, control | See detailed information in the Integration with Apollo SDK v.2 section | AAM Systems Office address: Kraznokazarmennaya str., 13-402 | SDK | RS-232, IP |
HID | EDGE ER40; VertX: v1000, v100, v200, v300, v2000, EVO Control reader HID Omnikey 5321 | Monitoring, configuration, control | 15370 Barranca Pkwy Irvine, CA 92618-3106 Tel.: (949) 732-2000 Toll Free: (800) 237-7769 Fax: (949) 732-2120 http://www.hidglobal.com | SDK | IP | |
Honeywell Galaxy Dimension | Galaxy GD-48 Galaxy GD-96 Galaxy GD-264 Galaxy GD-520 DCM | Monitoring, configuration, control | Honeywell Systems Group Tel: +44 (0)8448 000 235 Fax: + 44 (0)01928 754050 Email: sales.video.uk@honeywell.com | low-level protocol | RS-232, Ethernet |