The Web-server object is used for viewing the video surveillance information from an Internet browser and TCP/IP communication environment. The settings panel of the Web-server object is shown in figure.

Table describes the parameters of the settings corresponding to the elements of the settings panel of the Web-server object.

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Web-server object in the digital distributed video surveillance system.

Sequence of numbers

-

From 1 and above.

Depends on the number of the Web-server objects in the digital distributed video surveillance system.

2

Name*

Type-in the value in the field

Sets the name of the Web-server object in the digital distributed video surveillance system.

Latin, Cyrillic and service characters

Web- server

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Checkbox

Sets the state of the Web-server object (enabled or disabled) in the digital distributed video surveillance system.

Boolean type

No

Yes – the Web-server object is disabled and is not in use

No – the Web-server object is enabled and is in use

4

Computer

Selected in the list

Sets the parent Computer object of the digital distributed video surveillance system, to which the given Web- server object refers.

Name of the Computer objects registered in the system

Name of the parent Computer object

Depends on the number of the Computer objects in the digital distributed video surveillance system

The Cameras group

5

As in camera settings

Checkbox

Sets the transmission of video signal to Remote Workstations using the Web-server module. The compression level of this video signal is to be the same as it is for to the recorded and transmitted video signals or as it is set by the slider below the As in camera settings checkbox.

Boolean type

Yes

Yes – the compression level of the video signal transmitted with the Web- server module is be the same as the compression level of the recorded and transmitted video signal.

No – the compression level of the video signal transmitted with the Web- server module is the same as one set by the slider below the As in camera settings checkbox

6

Signal compression*

Set the slider in the required position

Sets the compression level of the video signal transmitted with the Web-server module to the Remote Workstations.  The higher the compression level, the lower the quality of video signal.

The parameter is active, only if the As in camera settings checkbox is unchecked (i.e., the As in camera settings parameter has No value).

 

Min

Min – the minimal compression level, at which the video signal is transmitted as a non-compressed video.

Max – maximum video signal compression level.

The HTTP-server group

7

Port’s number

Type-in the value in the field

Sets the number of the port used by the HTTP server (for video surveillance with the Web-browser via the Internet).

Sequence of numbers

80

Any allowable port numbers which are not in use.

The number of ports is defined by the system administrator.

8

Amount of connections

Type-in the value in the field

Sets the maximum allowable number of connections to the video server via the Web-server module.

Each request to view the camera feed and each request to control all PTZ devices is considered as a user connection.

pcs

100

Any integer.

In the case where 0 value is specified, video signals will not be displayed on the Web-server monitor.

The Mobile-server group

9

Port’s number

Type-in the value in the field

Sets the number of the port for Mobile-server operations.

Sequence of numbers

5003

Any allowable port numbers which are not in use.

The number of ports is defined by the system administrator.

10

Amount of connections

Type-in the value in the field

Sets the maximum allowable connections to the video server via the Web-server module.

Each request to view the camera feed and each request to control all PTZ devices is considered as a user connection.

pcs

100

Any integral number.

In the case where 0 value is entered, video signals will not be displayed in the Web server monitor.

The Cameras group

11

Camera

Selected in the list

Sets the name of the video camera video from which is transmitted to the Remote Workstation via the Web-server module.

Names of the Camera objects registered in the system

Not set

Depends on the number of video surveillance cameras in the digital distributed video surveillance system

12

Gate

Selected in the list

Sets the name of videogate video from which is transmitted to the Remote Workstation via the Web-server.

Note: If the Videogate has its own archive, then Web-server will get the archive from the Videogate archive, otherwise – from the main camera archive.

Names of the Videogate objects registered in the system

Not set

Depends on the number of videogates in the digital distributed video surveillance system

13

Microphone

Select from a list

Specifies the name of microphone associated with the camera from which the sound will be passed through the Web-server

Names of registered Microphone objects in the system

Not specified

Depends on the number of microphones in the video surveillance system

14

Speaker

Select from a list

Specifies the name of speaker associated with the camera which will be in use to playback sound received from the client

Names of registered Speaker objects in the system

Not specified

Depends on the number of speakers in the video surveillance system

15

Add all

Click the button

Adds all video cameras installed in the digital distributed video surveillance system to the list of cameras video from which is transmitted to the Remote Workstation via the Web-server

-

-

-

16

Clear

Click the button

Removes all video cameras from the list of cameras video from which is transmitted to the Remote Workstation via the Web-server

-

-

-

17

Default user

Selected in the list

Sets the user with rights and authorities to conduct video surveillance from the Remote Workstation via the Web-server

The names of users registered in the system and added to the rights

Not set

Depends on the number of users registered in INTELLECT™

*The name of the element is not displayed in the settings panel of the given object.