To configure the AR-725 controller, do the following:
From the Mode drop-down list select the required mode of the controller (3). Possible modes are presented in the table.
Mode | Networking/ Stand-Alone | User Capacity | Access Mode | Auto-show Duty time | Event log Capacity | 120 Holidays | Anti force | Time Zone | Lift Control | Anti-pass-back |
M4 | Networking/ Stand-Alone | 1,024/3,000 (725H) | 1.Card only. 2.Card and PIN (4-digit PIN)+#. 3.Card or User address (5-digit) + Individual PIN (4-digit individual PIN) + #. | Yes | 1200/1500 (725H)/3000 (757H) | Yes | Yes | 11 | 32 | Yes |
M8 | Networking/ Stand-Alone | 1,024/3,000 (725H) | 1.Card only. 2.Card and PIN (4-digit individual PIN) + #. 3.Card or PIN (4-digit individual PIN). | Yes | 1200/1500 (725H)/3000 (757H) | Yes | Yes | 11 | 32 | Yes |
From the RS 485 port functions dropdown list select the type of communication through the RS 485 port (8).
To connect the AR-725 controller with the ACFA Intellect software select «Host» value in the «RS 485 port functions» field (5). |
Configuring parameters of the AR-725 controller is completed.