To configure the Gate Parking controller, do the following:
From the Relay time: drop-down list select the time period in seconds during which the lock will be opened.
If the relay time equal to 0 the lock is failed to open by available ways: using the key, button or corresponding command. |
From the Access time: drop-down list select the time period in seconds during which the user can open the door.
Access time and relay time start to count off from the moment of relay trigerring (i.e. lock opening), so the access time can’t be less than relay time. |
From the Time of holding open: drop-down list select the time period in seconds after door opening during which the door is to be closed.
If the door will not be closed after time of holding open expire then the Door not closed events is fixed. It is followed by signal and light indication till the door will be closed. |
From the Confirmation time: drop-down list select the time period in seconds during which access is to be confirmed by card (see Configuring Gate Parking access modes section).
If the confirmation time is 0 the confirmation timeout is not limited. |
Configuring parameters of the Gate Parking controller is completed.