Intellect Web Report System

XML fileParameterAvailable valuesDefaultParameter in effect
<Directory of the Intellect software installation>\Modules\Wt2\Web.configCamMonitorShift-5000 - 50000

Sets shifting of video start while report viewing in milliseconds:

>0 – video will start later than time specified in a report

<0 – video will start earlier than time specified in a report

FaceReplaceCameraIpFromIP-address-Changes internal IP-address of a Server specified in the Architecture while viewing video for POS reports and for "Face" module report from outside
FaceReplaceCameraIpToIP-address-Changes external IP-address of a Server specified in the Architecture while viewing video for POS reports and for "Face" module report from outside