The Security zone panel is designed to define the common settings of the Intellect™ system. The settings panel of the Security zone object is shown in the figure.

 

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Security zone object.

 

Parameter

Method for entering the parameter

Parameter description

Symbols used

Default value

Value range

The Settings group

1

Event database length

Type-in the value in the field

Sets the number of days for keeping the information about the events registered by the Intellect™ system and recorded in the Event log. This parameter influences on all computers in the distributed system.

Days

3

Not less than 0

2

Facility code

Type-in the value in the field

Defines the number of the access control card, which is automatically displayed in the User settings panel, when the object is being created in the Facility code field.

Sequence of numbers

Not defined

More than 1

3

Run macro at startup

Is selected from the list

Defines the macro command, which will be automatically launched with the Intellect™ system startup.

Names of the Macro command objects registered in the system

Not defined

Depends on the number of Macro command objects created in the digital distributed video surveillance system.

4

Connections in the architecture

Is identified by the check mark

Defines the computers for displaying the Computer object, which will be created, either on all computers of the digital distributed video surveillance system, or only on the Computer object, used as a base to create the given object.

Boolean type

Not available

Yes – the object, which will be created, will be shown in the architecture of all computers of the digital distributed video surveillance system.

No – the object, which will be created, will be shown only in the architecture of the Computer object used as a base to create the given object.

5

Offline synchronization

Checkbox

Enables offline synchronization of events

Boolean type

Yes

Yes – offline synchronization is enabled. When the computer is reconnected, it gets all the events for the period there was no connection.

No – offline synchronization is disabled. When the computer is reconnected, it does not get the events for the period there was no connection.

6

Administrator’s password

The button is pressed

Gives a command to open a dialog box for assigning the Administrator’s password.

-

-

-

Holidays group

7

Date*

-

List of calendar days which will be defined as holidays in the Intellect software

Date

Not specified

Date format:: DD-MM-YY

8

Add

Click the button

Opens the Calendar dialog box to set the date of new holiday

-

-

-

9

Delete

Click the button

Deletes the selected holiday date from the Date list

-

-

-

10

Change

Click the button

Opens the Calendar dialog box to change the selected holiday date in the list

-

-

-

*The name of the element is not displayed in the settings panel of the given object.