In the Store ___ events field, set the maximum of events displayed in the Operator protocol interface box (8).
The number of events displayed in the Operator protocol interface box affects the main memory capacity. If 100 non-processed events are displayed in the interface box, then the Operator protocol module can use up to 200 Mb of main memory. When the value of the Store ___ events parameter is increased, the main memory capacity is increased too. |
Select the object type in the list of the Type column.
Only objects for which the "INFORMATION" or "ALARM" value is selected in the Processing messages column on the Events tab in the ddi.exe utility are available for selection (see The Events tab section). |
In the list of the Event type column, select events that are to be displayed in the protocol box. If the event type is not specified, then all events registered by the selected object will be transmitted to the protocol. Only alarm and informative events are in this drop-down list.
If the processing of an event is to be confirmed with a password, select the Yes value in the Request password drop-down list. If there is no need to confirm the processing with a password, select the No value in this drop-down list.
If the processing of all events is to be confirmed with a password, set the Password for closing checkbox (13). |
Repeat actions described in step 9 for all required objects. To add a line, go to the last line of the table and click the ↓ key.
To remove the lines from the table, use the Ctrl + Del key combination. |
In the DB tab, configure the connection to the database server (5).
Parameters, set at INTELLECT ™ software installation, are used by default to connect to the database server. |
In the Server field, set the name of the database server to connect to (1).
Working in the distributed configuration it is needed to enter the name of computer without the (local) value where the database is stored. For example, "WS1\SQLEXPRESS", where WS1 – the name of computer on which the database is stored. |
The Operator protocol object is now configured.