The Queue length detection module can be configured using the System settings menu, under the Hardware tab, on the Queue Length Detection control panel, using the Camera settings.
The Queue length detection module is set up as follows:
Using the left mouse button select the four corners of the area on the captured video image (3) to be analyzed (1). Only one area may be so designated. If a second area is specified, then the first area will be deleted. Upon selection of the area the remaining part of the video image will be dimmed.
To remove a selected area, click the |
On the captured video image (1) specify the approximate size of a person. To do this use the left mouse button to specify a rectangular area (1).
To remove the person size, click the |
In the Periodicity of employment measuring, s field, enter a time period in seconds for counting the number of persons in the observed area (2). Minimum value of this parameter is an interval between frames of analyzed video stream, but not less than 1 second and not more than 3600 seconds. Value of the parameter depends on scene characteristics. For example, if a queue in the field of video camera view is not changing for a long time, than the parameter value can be reasonably large. It is not recommended to specify value of this parameter more than 3-5 minuts for correct working of algorithm on the average scene.
The more frequently employment measurings, the more frames are analyzed by algorithm and the higher the system capacity. |
Click OK to save changes and return to the control panel of the Queue length detection (5).
To return to the control panel of the Queue length detection without saving changes, click Cancel (6). |
Configuring the Queue length detection module is complete.