Settings panel of the Monitoring interface object is given on figure.
Description of the Monitoring object settings panel elements is given in table.
# | Name | Method for setting the parameter value | Description | Type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Identifier | Automatically | Shows the identification number of the Monitoring object in the system | Nonnegative integer | - | >=0 |
2 | Name | Enter the value in the field | Shows the name of the Monitoring object in the system | Latin, Cyrillic letters and service characters | Monitoring | A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. |
3 | Display | Is selected in the list | Assigns the parent Display object for the Monitoring object | Names of Display objects registered in the system | Name of the parent Display object | Depends on the number of the Display objects in the system. |
4 | Owners panel | Is set in a checkbox | Enables Owners panel displaying | Boolean | True | True - Owners panel is displayed False - Owners panel is hidden |
5 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Owners panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
6 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Owners panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
7 | W: | Enter the value in the field | Set the width of the Owners panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
8 | H: | Enter the value in the field | Set the height of the Owners panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
9 | Control panel | Is set in a checkbox | Enables Control panel displaying | Boolean | True | True - Control panel is displayed |
10 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Control panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
11 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Control panel interface box | % of the screen height | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
12 | W: | Enter the value in the field | Set the width of the Control panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
13 | H: | Enter the value in the field | Set the height of the Control panel interface box | % of the screen height | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
14 | Log panel | Is set in a checkbox | Enables Log panel displaying | Boolean | True | True - Log panel is displayed |
15 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Log panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
16 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Log panel interface box | % of the screen height | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
17 | W: | Enter the value in the field | Set the width of the Log panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
18 | H: | Enter the value in the field | Set the height of the Log panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
19 | Non-empty Comment field | Is set in a checkbox | Is set to require that operators leave comments when accepting an alarm to describe the alarm and/or their actions | Boolean | True | True - Comment field shall not be empty on alarm accepting |
20 | Use filter by events | Is set in a checkbox | Is set to enable filtering objects by Alarm and Failure events and Connected and Disconnected states. on the Control Panel. | Boolean | True | True – filter can be applied. False – filter cannot be applied. |
21 | Warning when watching live video | Is set in a checkbox | Is set if when live video is attempted to be viewed from Control Panel it is necessary to display a warning that it can create the critical load per data channel | Boolean | True | True - when live video is attempted to be viewed from Control Panel the warning is displayed |
22 | Viewing live video through gateway | Is set in a checkbox | If set if Agents of Control and Additional workplaces are in different subnets and the Monitoring components are not in a distributed system configuration in Intellect object tree and Data gateway is in use for transmission of live video to Additional workplaces | Boolean | False | True – live video is transferred to the Additional workplaces through the data gateway. False – live video is transferred to the Additional workplaces directly from the Agent of Control. |
23 | Video stream speed | Enter the value in the field | Sets the frame rate for live video displaying | Frames per second | 25 | Depnds on the camera features |
24 | Compression | Select from the list | Sets live video compression rate | Supported compression rates | No | 0-5 |
25 | Groups of alarms | Is set in a checkbox | Sets alarms that one want to visualize on the Control panel | Boolean | All checkboxes except the Temperature sensors are set | If checkbox is set next to the group of alarms, then alarm from the corresponding group will be displayed on the Control panel |
26 | Filter by owners | Via the Filters... button | Displays selected pairs of users and owners | - | - | - |
27 | Filter... | Click the button | Opens a dialog box to match owners to users | - | - | - |