The settings panel of the User permissions object is shown in the figure.
Elements of the settings panel of the User permissions object are described in the table.
№ | Parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range | |
1 | The ID field* | Automatically | Displays the identification number of the User permissions object in the system | Sequence of numbers | - | Depends on the number of the User permissions objects in the system. | |
2 | The Name field* | Enter the value in the field | Sets the name of the User permissions object in the system | Latin, Cyrillic and service characters | User permissions | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. Number of symbols – from 1 to 60. | |
3 | The Disable checkbox | Set the checkbox | Defines the status of the User permissions object (enabled or disabled) in the system | Boolean type | No | Yes – the User permissions object is disabled and is not in use. No – the User permissions object is enabled and is in use. | |
The Configuring group | |||||||
4 | The group of Tabs* checkboxes | Set the checkbox | Specifies the tabs of the System settings dialog box that can be accessed when the User gets the corresponding rights | Boolean type | All checkboxes are set unchecked | The following values are available for each tab: Yes – User is allowed to manage the objects in the tab. No – access to the tab is forbidden. | |
5 | The Ask user password for shutdown system checkbox | Set the checkbox | Allows shutting down Intellect using the password of the authorized User | Boolean type | No | Yes – User with these rights is allowed to shut down Intellect No – User with these rights is not allowed to shut down Intellect | |
6 | The Ask administrator password for system shutdown checkbox | Set the checkbox | Allows shutting down Intellect using the password of the Administartor | Boolean type | No | Yes – Intellect shuts down only when the Administrator password is in use No - Intellect shuts down in various ways | |
7 | The Forbid to hide interface checkbox | Set the checkbox | Allows hiding interfaces in Intellect | Boolean type | No | Yes – interfaces cannot be hidden No – interfaces can be hidden | |
8 | The Relogin prohibited checkbox | Set the checkbox | Allows changing the user in Intellect | Boolean type | No | Yes – User can be changed No – User cannot be changed | |
9 | The list of system objects* | Automatically | Displays the objects created in the system and allows setting the administration and monitoring rights | - | - | - | |
The Connection with AD group | |||||||
10 | The Connection with AD button | Click the button | Opens a dialog box to configure correspondence between Intellect user permissions and Windows Active Directory | - | - | - | |
The Access to archive group | |||||||
11 | The Depth __ last hours field | Enter the value in the field | Sets the number of last hours of video archive that can be viewed | Nonnegative integer | - | >=0 0 means that viewing the archive is prohibited | |
12 | The Since last access checkbox | Set the checkbox | Sets the time to define the archive depth
| Boolean type | No | Yes – hours available for viewing are counted since the User logged in No - hours available for viewing are counted since the current moment | |
The Access to backup archive group | |||||||
13 | The Depth __ last hours field | Enter the value in the field | Sets the number of last hours of backup archive that can be viewed | Nonnegative integer | - | >=0 0 means that viewing the backup archive is prohibited | |
14 | The Since last access checkbox | Set the checkbox | Sets the time to define the backup archive depth | Boolean type | No | Yes – hours available for viewing are counted since the User logged in No - hours available for viewing are counted since the current moment | |
No group | |||||||
15 | The Allow video archive files remove checkbox | Set the checkbox | Defines whether video archive files can be removed from the Monitor interface | Boolean type | No | Yes – The “Remove video from the feature menu” item is available in the Monitor No – removing video from the feature menu is not available | |
16 | The Allow rewrite protection checkbox | Set the checkbox | Sets possibility of rewrite protecting of files | Boolean type | Yes | Yes – operator added to these permissions can protect archive records against loop recording No – operator cannot protect archive records against loop recording | |
17 | The Allow to disable file protection checkbox | Set the checkbox | Sets possibility to disable rewrite protection of files | Boolean type | Yes | Yes – operator added to these permissions can reset rewrite protection of files No – Operator can't reset rewrite protection of files | |
18 | The Allow export checkbox | Set the checkbox | Sets possibility to export protected records | Boolean type | Yes | Yes – Operator added to these permissions can export video recordings. No – Operator cannot export video recordings. | |
19 | The Log out if inactive for __ minutes checkbox and field | Set the checkbox, enter the value in the field | Sets the time period (in minutes) when the operator is inactive - at the end of this period the session is to be terminated | Boolean type, integer | No | Yes – when the operator is inactive for the specified time period, session is not automatically terminated. To continue operation, log in the system specifying the username and password. No – session is not automatically terminated when the operator is inactive. | |
20 | The ONVIF dropdown list | Select the value in the list | Sets user rights to use the ONVIF Server | Supported types of permissions | - | Administrator Operator User | |
21 | The Import rights button | Click the button | Configure import of user permissions settings from several other User permissions objects. | - | - | - |
* The name of the object is not displayed on the settings panel