The MorphoAccess SIGMA Lite controller mode is selected as follows:
In the Mode drop-down list (1), select the operation mode:
GPIO is a general purpose input/output (for details about setting up this operation mode, see Configuring the MorphoAccess SIGMA Lite controller in GPIO mode).
SDAC is a single door access control (for details about setting up this operation mode, see Configuring the MorphoAccess SIGMA Lite controller in SDAC mode).
In the Timeout open door field (2), enter the time in seconds within which the door will be opened after user authentication.
Selecting the MorphoAccess SIGMA Lite controller mode is complete.