From the Video drop-down list (7), select the method of the video displaying from the operator’s protocol:
ActiveX - archive and live video will open in a separate window.
Monitor - archive and live video will open on the selected Video Surveillance Monitor.
In the Store ___ events field, set the maximum of events displayed in the Operator protocol interface box (9).
The number of events displayed in the Operator protocol interface box affects the main memory capacity. If 100 non-processed events are displayed in the interface box, then the Operator protocol module can use up to 200 Mb of main memory. When the value of the Store ___ events parameter is increased, the main memory capacity is increased too. |
If it is necesary to automatically activate the last received event, set the Autoactivation of last event checkbox (16).
By default, the comment entered by the operator when assigning a type to an event, is not deleted. If it is necessary to clear the comment field after processing the event, set the Clear comment checkbox (17).
By default, the alarms are displayed in the Operator Protocol window as the tiles of a specified size. If it is necessary to enlarge the alarm tile to the entire window size (except for the event control panel), set the Fit window size checkbox (18).
If it is necessary to prohibit the Operator from processing all alarms at once, set the Hide "Apply to all" checkbox (19).
Select the object type in the list of the Type column.
Only objects for which the "INFORMATION" or "ALARM" value is selected in the Processing messages column on the Events tab in the ddi.exe utility are available for selection (see The Events tab section). |
In the list of the Event type column select events that are to be displayed in the protocol box. If the event type is not specified, then all events registered by the selected object will get to the protocol.
If the processing of an event is to be confirmed with a password, select the Yes value in the Request password dropdown list. If there is no need to confirm the processing with a password, select the No value in this dropdown list.
If the processing of all events is to be confirmed with a password, set the Password for closing checkbox checked (14). |
Repeat actions described in step 9 for all required objects. To add a line go to the last line of the table and click the ↓ key.
To remove the lines from the table use the Ctrl + Del key combination. |
In the Checklist table, enter the description of the actions that the operator must perform before assigning the status to an event (22). These actions will be displayed in a special field in the Operator Protocol interface, and the Operator will be able to mark their completion.
In the DB tab configure the connection to the database server (5).
Parameters set at INTELLECT ™ software installation are used by default to connect to the database server. |
In the Server field set the name of the database server to connect to (1).
Working in the distributed configuration it is needed to enter the name of computer without the (local) value where the database is stored. For example, "WS1\SQLEXPRESS", where WS1 is the name of computer on which the database is stored. |
On the Interface tab (4), configure the interface settings:
From the Frame drop-down list, select the frame color of the active event tile (1).
If it is necessary to set the custom names for the alarm processing buttons, enter the button names in the left fields of the Situation buttons group (2).
If it is necessary to assign the hot keys for the alarm events processing, set the cursor in the right field of the Situation buttons group (3) and press the required key combination. It is allowed to combine the Ctrl, Alt and Shift keys with any other keys on the keyboard. For example, the Ctrl+Shift+Alt+A or the Ctrl+A shortcuts are allowed, but the D+A or D+Ins shortcuts are not allowed, etc.
The Operator protocol object is now configured.