The following designations are in the reference guide:

(x32) - HKEY_LOCAL_MACHINE\SOFTWARE\ITV\INTELLECT\ registry section

(x64) - HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ITV\INTELLECT registry section

For the ATM-Intellect software:

(x32-ATM/Monitoring) – HKEY_LOCAL_MACHINE\SOFTWARE\BitSoft\VHOST\VHostService registry section

(x64-ATM/Monitoring) – HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\BitSoft\VHOST\VHostService registry section

For the ATM Event Capture utility:

(x32-ATM Event Capture) – HKEY_LOCAL_MACHINE\SOFTWARE\ITV\EventATM registry section

(x64-ATM Event Capture) – HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ITV\EventATM registry section


 

 

General information on Windows OS registry and working with it is given in the Working with Windows OS registry section of the Administrator's Guide.


Audio

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\Audio
x64: (x64)\Audio

Gain_control

0, 1, 2

-

up to  4.7.6

Sets the volume control parameter: 

0 - no volume control;
1 - integer processing (less accurate, but faster);

2 - extra accuracy (CPU overload is possible if there are a lot of channels).

x32: (X32)\Audio
x64: (x64)\Audio

Max_file_len_sec

 > = 0

 600

4.7.4 and later

Defines max. length of audio file (sec) when recording via audio player.

x32: (X32)\Audio\
Card\ «Card Name»
x64: (x64)\Audio\Card\ «Card Name»

 

mix

0, 1

0

4.7.4 and later

Sets input mixing.

x32: (x32)\Audio
x64: (x64)\Audio
AudioStreamLoggerEnable0, 104.9.8 and later

0 – logging is disabled.

1 or other value different from 0 – streams logging is enabled.

The module restart is not required to change the key value.

TABLE OF CONTENTS

 

Core

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (x32)
x64: (x64)

ChangePort

> = 0

Depends on the port specified for the Client.

4.7.3 and later

Allows changing the port number. For instance, if it is necessary to change port 20900 to 40900, then 20900="40900" string parameter is created.
The change of this parameter can affect the system.

x32: (x32)
x64: (x64)

CheckPingPeriod

> 0

 10

4.7.4 to 4.10.2

Sets Server-computer ping period.

Note. In Intellect since version 4.10.3 this parameter is set on the settings panel of the Security zone object.

x32: (x32)
x64: (x64)

CheckVersion

0, 1

0

4.7.4 and later

Sets the parameters of Server connection: the version is checked in connected version parameters. If versions do not agree, then there is a corresponding message and no connection.

x32: (x32)
x64: (x64)

Core IP Address

IP address

 -

4.7.3 and later 

Address of the computer to the core of which the slave.exe is to connect.

x32: (x32)
x64: (x64)

DBAttempts

1..∞

 10

4.7.3 and later

Number of attempts to connect to database.

x32: (x32)/Debug
x64: (x64)/Debug

DebugLevel

0,1,2,3,4

0

4.7.3 and later

Sets the debug mode:
0 – disabled;

1 – information is shown in the process window;

2 – information is shown in the process window and logged;

3 – extended log is written – it contains module events;

4 – extended log is written – it contains module events and parameters.

x32: (x32)/Debug
x64: (x64)/Debug

DebugExtension

Any string

LOG

4.7.3 and later

Sets extensions of log files.

x32: (x32)/Debug
x64: (x64)/Debug

DebugFlushPeriod

> = 0

500

4.7.4 and later

Sets the update rate for log files (ms).

x32: (x32)/Debug
x64: (x64)/Debug

DebugOptions

Range in decimal system: 0-255. 

0x001 (i.e. 1)

4.7.3 and later

Hexadecimal logging in the debug mode. This parameter has a complex structure (bit mask) and it is modified using the Tweaki.exe utility.

x32: (x32)/Debug
x64: (x64)/Debug

DebugQueueMaxLines

0 - 2147483647

2000

4.7.4 and later

Specifies max. number of messages in a queue to log file. If there are more than 500 log lines in the queue, then they are to be scaled.

x32: (x32)/Debug
x64: (x64)/Debug

DebugSize

>=100

100

4.7.3 and later

Specifies the number of megabytes provided for log. Restricted by disk capacity.

x32: (x32)/Debug
x64: (x64)/Debug

DebugTime

 0-2147483647

48

4.7.3 and later

Specifies the number of hours for keeping log files.

x32: (x32)/Debug
x64: (x64)/Debug
DebugZipDays>024.7.5 and laterSpecifies the number of days for keeping log files in the gz format.

x32: (x32)
x64: (x64)

defaultconnection

 0, 1

1

4.7.4 and later

Allows setting connections in the architecture only with the computer where the Computer object is created.

x32: (x32)
x64: (x64)

DisableProtocol

0, 1

0

4.7.3 and later

Allows disabling protocol.

x32: (x32)
x64: (x64)

DisableThreadStatQueue

0, 1

0

4.8.0 and later

 

By default the key is not created.

 

Defines whether the queue statistics is called or not. If the registry key value=1, then the box can not be called.

 

To call the Queue statistics box, follow the steps:

 

  • Intellect 4.9.2 and older – press F2
  • Intellect 4.9.3 and later – press Alt+F2 key combination


x32: (x32)
x64: (x64)

InstallFolder

 

Intellect

4.7.3 and later

Specifies the installation folder.

x32: (x32)
x64: (x64)

Ip_port

0, 1

 

up to  4.7.6

Specifies the port using which the IP camera will operate on the Computer object.

x32: (x32)
x64: (x64)

Language

0x0419

-

4.7.3 and later

Specifies the language to use (0x0419 - English). 

x32: (x32)
x64: (x64)

LogIncommingMsg

0, 1

not created

up to  4.8.0

Defines whether logging of incoming events is enabled or not.

x32: (x32)
x64: (x64)

LogOutgoingMsg

0, 1

not created

up to  4.8.0

Defines whether logging of outgoing events is enabled or not.

x32: (x32)
x64: (x64)

LogStatistics

0, 1

not created

up to  4.8.0

Defines whether the statistics is logged or not.

x32: (x32)
x64: (x64)

OnlyLocalProtocol

0, 1

0

4.7.3 and later

Only local events are logged.

x32: (x32)
x64: (x64)

PeakWorkingSetSizeQuota

>=0

0

4.8.1 and later

Sets RAM limit (MB). When this limit is exceeded, the module that exceeded this limit will be restarted in the restart service.

x32: (x32)
x64: (x64)

PhotoCores

Name or IP address 

-

4.7.3 and later

The list of computers (cores) for mailing user photos.

x32: (x32)
x64: (x64)

PriorityClass

256,

128,

32768,

32,

16384,

64

 16384

4.7.3 and later

Defines the stream priority:

256 - realtime

128 - high

32768 - Above Normal

32 - normal

16384 - below Normal

64 - low

x32: (x32)
x64: (x64)

ShowCrashMessage

0, 1

0

4.7.5 and later

Create or not the module crash message. 

x32: (x32)
x64: (x64)

SyncTime

0, 1

0

4.7.3 and later

Defines whether to synchronize time between computers or not.

x32: (x32)
x64: (x64)

Topmost

0, 1

1

4.7.4 and later

Sets the splash screen location:
1 - splash screen is topmost;
0 - screen is hidden behind other windows.

This key is applied for splash screen on the Server/Remote Administrator’s workplace for Intellect versions older than 4.10.0, for versions newer 4.10.1 - both on the Server/Remote Administrator’s workplace and on the Client.

x32: (x32)
x64: (x64)

Type_view_dept_log

0,1,2

0

4.7.4 and later

Specifies displaying the  name of department in the log:

0 - do not add:  Ivanov Ivan Ivanovich;  
1 - add to the beginning:
[Sales department] Ivanov Ivan Ivanovich;
2 - add to the end:
Ivanov Ivan Ivanovich [Sales department].

x32: (x32)
x64: (x64)

URAttempts

 0 - 10000

3

4.7.3 and later

Sets the number of attempts to enter the user password .

x32: (x32)
x64: (x64)

URDelay

 0 - 10000

60

4.7.3 and later

Sets the delay period (sec) for re-entering the system.

x32: (x32)
x64: (x64)

virtualgrabber

0, 1

0

4.7.6 and later

Defines whether it is possible to create  a virtual video capture card or no.

x32: (x32)
x64: (x64)

SyncNotEmpty

0, 1

0

4.8.5 and later

Defines the database synchronization algorithm:

1 – fast synchronization algorithm is in use;

0 -  standard synchronization algorithm is in use.

x32: (x32)\Debug
x64: (x64)\Debug

counter_period

>=0

0

4.9.0 and later

Defines the time period in seconds, in which information about availability of processor, memory and disk is recorded to the log-file. If the value of parameter is 0, this information is not included to the log-file.

x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService

RestartIntellectOnLogonDisable

0, 1

0

4.9.0 and later

1 – Intellect installed as a Service is not restarted under the current user even for users belonging to the IntellectUsers group.

0 – Intellect installed as a Service is restarted under the current user only if the user belongs to the IntellectUsers group.

x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService

CheckUserForRestartIntellectDisable

0, 1

-

4.9.0 and later

0 – Intellect installed as a Service is restarted (when entering the system) under the current user only if the user belongs to the IntellectUsers group.

1 – Intellect installed as a Service is restarted (when entering the system) under the current user even if the user doesn’t belong to the IntellectUsers group. The settings of permissions are to be taken into account when using this key. If the permissions are set incorrectly, then some Intellect features can operate incorrectly.

x32: (x32)
x64: (x64)

ShowHiddenObjects

0, 1

0

4.9.0 and later

0 – hidden objects corresponding to IntegratedAudioSource and IntegratedVideoSource objects, as well as to Integrated device child objects are not shown in the object tree in Intellect.

1 – hidden objects are shown in the object tree in Intellect.

Intellect is to be restarted when the key value is changed.

x32: (x32)
x64: (x64)

InheritServiceEnviroment

0, 1

-

4.8.8 only

The key is essential for proper operation of Intellect in MS failover cluster.

x32: (x32)\ IntellectRunService\
x64: (x64)\ IntellectRunService\

InheritServiceEnvironment

0, 1

-

4.9.0 and later

The key is essential for proper operation of Intellect in MS failover cluster.

x32: (x32)
x64: (x64)

SortCamsById

0, 1

-

4.8.8 and later

The key is responsible for sorting the list of cameras on the settings panel of the Monitor object.

1 – cameras are sorted by ID;

0 – cameras are sorted by names.

x32: (x32)
x64: (x64)

EventProcessingThreads

>=0

0

4.9.0

Key reserves the specified number of streams for events processing.

0-8Equal to CPU cores number4.10.4

x32: (x32)\Debug
x64: (x64)\Debug

DumpYUV

0, 1

-

4.9.0.959

Key activates the mode of video dump corresponding to compressor.  It is required for diagnostics of StreamLabs (motionWavelet7.1) compressor/decompressor problems.

File (or files) with decompressed data will be created by key in the Modules directory. Names of files correspond to the template:
WxH_hv_chunk_№.yuv

W – width;
H – height;
h – horizontal subsampling;
v – vertical subsampling;
№ - number of file. If resolution or subsampling are changed the new file openes.

For example, file with resolution 640x480 in YUV420 color area will have the 640x480_22_chunk_0.yuv name.

x32: (x32)
x64: (x64)

settings_height>0, depends on screen resolution438 Sets the height of the object settings panel (in pixels).

x32: (x32)
x64: (x64)

settings_width>0, depends on screen resolution600 Sets the width of the object settings panel (in pixels).
x32: (x32)
x64: (x64)
ATMSendSetup0, 114.9.3

0 – receiving of the SETUP reaction from the ATM object is disabled on the computer where this key is specified.

1 - receiving of the SETUP reaction from the ATM object is enabled on the computer where this key is specified. 

x32: (x32)
x64: (x64)
RegisterF10andF110, 114.9.2

1 - F10 and F11 hot keys are in use to control screen displaying (see Main control panel section).

0 - F10 and F11 hot keys are not in use to control screen displaying.

Note.When the key is changed Intellect restart is required. 

 To disable F10 and F11 hot keys on the Administrator Remote Workplace, the key is to be created in the  \HKEY_CURRENT_USER\Software\ITV\Intellect registry section.

To disable F10 and F11 hot keys on the Administrator Remote Workplace when operating under the Admin account, he key is to be created in the same registry section as on Server (x32)/(x64).

x32: (x32)
x64: (x64)
DisableF80, 104.10.4

0 -  F8 hot key is in use to call the Execute menu on the main control panel.  

1 - F8 hot key is not in use.

Note. To disable F8 hot key on the Administrator Remote Workplace, the key is to be created in the  \HKEY_CURRENT_USER\Software\ITV\Intellect registry section.

To disable F8 hot key on the Administrator Remote Workplace when operating under the Admin account, he key is to be created in the same registry section as on Server (x32)/(x64).

x32: (x32)
x64: (x64)

check_digital0, 104.8.0

When the key value = 1, video or archive period is exported from the Monitor interface using the admin password.

x32: (x32)
x64: (x64)
CONNECT_ATTEMPTS>=114.9.4The key sets the number of attempts to connect the Client to Server. The key is specified on the side of the Client.
x32: (x32)
x64: (x64)
FLUSH_TIMER_TIMEOUT>0

By default the key is not created, the value is 10.

4.9.4

The key specifies maximum waiting time (in milliseconds) before sending data over the network.

The higher the value of this parameter, the more productive the system is (due to decreasing resources when sending a large amount of small messages).

However, time of response to events can also increase.
x32: (x32)
x64: (x64)
UnloadDelay0 to 60000 ms50004.9.5

The key sets the delay between disabling Guardant and unloading Intellect.

The delay is essential for the FORCED_OFF event generation of the SLAVE object and in case this event is used in scripts or programs, these scripts and programs are executed.

If UnloadDelay = 0, unloading is performed without any delays, i.e. script/program in which the specified event is used, cannot execute.
x32: (x32)
x64: (x64)
SortSubItems0, 11-

The key is for specifying the way of sorting objects in the tree:

0 – sorting by name.

1 – sorting by ID.

Note 1. If sorting by name is chosen, and there are numbers in the object name, then the objects will be sorted in alphabetical order. For example, an object with the name "115" will be above the object with the name "15", because in the name "115" the second number is 1, and in the name "15" the second number is 5.

Note 2. This key also affects the sorting of objects in the tree when adding the objects to a layer in the Map Editor utility.

x32: (x32)
x64: (x64)
RestPort0 - 6553510112from 4.10.1 to 4.10.2Sets the port through which Intellect receives events and reactions via HTTP request. See also Sending reactions and events to Intellect using HTTP request.
0from 4.10.3
x32: (x32)
x64: (x64)
ShowSmallBarAlways0, 104.10.1

The key enables displaying the main control panel of Intellect on the screen.

0 – the main control panel is displayed when pointing to the upper right corner of the screen.

1 – the main control panel is always displayed in the upper right corner of the screen.
x32: (x32)
x64: (x64)
UpdateProtocolPeriod> 0-4.10.2

Sets time period (in days) of storing the change protocol in the database.

The storing period is counted from the last recording or starting from the current time depending on the value of the ClearProtocolFromCurrentTime key (see above).

Recordings storing period of which has expired are deleted at midnight every 24 hours in case the license is activated.
x32: (x32)
x64: (x64)
permissible_memory_limit>0-4.10.3The key sets the occupied memory threshold, reaching which the core starts receiving messages with a delay. The key should be used when due to excessive memory consumption, the module shuts down.
x32: (x32)
x64: (x64)
MsgCompressOn0, 104.10.3

The key enables the compression of transmitted messages:

0 - compression is disabled.

1 – messages from the cores are sent compressed (zip with maximum compression). Compression allows reducing the network load.

x32: (x32)
x64: (x64)
user_card_info_on0, 10Intermediate versions 4.10.3

The key is used with the ACS/FAS integration modules that are the part of ACFA Intellect. It enables displaying the access card number for all events associated with the cards in the Event Viewer.
0 - the access card number is not displayed in the Event Viewer.
1 - when an event comes from the ACS device, the param1 parameter is interpreted as an access card number and is displayed in the Event Viewer in the Card column. This column is automatically added to the Event Viewer window when the first such event is received.

Note. In the released version 4.10.3 to show and hide the Card column use the Hide Card checkbox – see Event viewer parameters.

x32: (x32)
x64: (x64)
CriticalErrGui0, 104.10.3It enables displaying messages about database connection errors regardless the debugging mode (see the description of the Debug key and Selecting and enabling the debug mode of Intellect software section).
0 - messages about database connection errors are displayed only at Debug 4 debugging levels.
1 - messages about database connection errors are displayed regardless the selected debugging level.
x32: (x32) 
x64: (x64)
IntellectCloseTimeout>0600004.8.3It sets Intellect close timeout in milliseconds. If intellect.exe process does not close during this timeout, then it is terminated forcefully. If there is no key, then timeout is 60 seconds.
x32: (x32)
x64: (x64)
SaveIncommingMsg0, 104.7.8

It enables recording of incoming messages to log files for started modules. The file name looks like <module name>.exe.cd.log.

These files are stored in the same folder as the executed module file, for instance, for intellect.exe the intellect.exe.cd.log file is stored in the Intellect installation directory and for itvscript.exe the itvscript.exe.cd.log file is stored in the Modules folder.

When the size of the log file exceeds 4 GB, it is archived to the backup file with .bak extension - <module name>.exe.cd.log.bak. This is necessary to avoid module overload.

Note. The log file is rewritten when Intellect is restarted.

0 – recording of incoming messages is disabled.

1 – recording of incoming messages is enabled.

x32: (x32)
x64: (x64)
BackupFolderAddress of a local or network folder-4.7.6Specifies the address of the folder to save a backup copy of the database created by a macro or using the idb.exe utility.
For example, C:\Documents and Settings\AVP\Desktop\Backup

If the database copy is to be stored on the network disk, then the UNC path to the network folder (with the recording access) is to be specified on the disk in the \\ServerName\ShareName format. Take into account the fact that all network resources that require additional authentication are to be enabled using the same username as for running the SQL Server service.

See also Creating the database backup copy

х32 and x64:

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon

ShellAny text valueexplorer.exe4.10.5If the key value contains the "explorer" string (for example, the default value, "testexplorertest" or "123explorertest125" values), the Save button is displayed in the About program... window. Otherwise, the Save button is hidden.
x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService
IntellectUserGroupAny text value
from 4.10.0If Intellect is installed as a Service, and you need to use a user group other than IntellectUsers, then specify the required user group name in this key.
x32: (x32)
x64: (x64)
monitor_refresh_delay10 -300003000from 4.10.5

The key sets a period in milliseconds to update video on Video Surveillance Monitors of the Clients after Failover Service has transferred configuration.

If the key value is less than 500, the monitors are updated regardless of the number of cameras.

If the key value is more than 500 and the number of cameras on the monitor is more than 64, the update does not occur while the System Settings dialog box is open.

x32: (x32)
x64: (x64)
DisableUpdateProtocol0, 10from 4.7.5The key disables the filling of the UPDATE_PROTOCOL table storing information about changes of Intellect object settings (except the User objects).
0 – the UPDATE_PROTOCOL table is filled.
1 – the UPDATE_PROTOCOL table is not filled.

TABLE OF CONTENTS

 

Telemetry

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

Delay

> = 0

250

4.7.3 and later

Defines the delay (ms) when sending commands to the camera. This key is essential for scaling the stream of commands to the device as some devices can be blocked because of too many commands and cannot process the information.

 

This parameter is not supported by IP cameras.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

JoysticThreshold

> = 0

5

4.7.6 HOTFIX and later

This parameter sets the joystick trigger threshold: the less the number is, the more sensitive joystick is.

0 value is not recommended to be used, as commands can be sent randomly.  When the value is too big, the joystick becomes rotation-insensitive.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

max_speed

0-10

-

4.7.3 to 4.9.7

Sets max. camera speed.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

min_speed

0-10

-

4.7.3 to 4.9.7

Sets min. camera speed.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

PriorityDelay

> =  0

30000

4.7.3 and later

Defines the priority delay (ms).

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

UseBoschOSRD40

0, 1

-

4.8.4 and later

Enables presets saving for Bosch-Autodome control protocol.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

PnPJoystick

0, 1

0

4.8.3 and later 

The key defines whether to restart Intellect after connecting a joystick:

0 - Intellect is to be restarted after connecting the joystick.
1 - Intellect is not to be restarted after connecting the joystick.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

Zenable

0, 1

1

4.7.7 and later 

The key is in use with joysticks (e.g., Logitech Attack 3) where the telemetry control operates incorrectly because of shifted Z axis. Z axis is disabled when the parameter value is 0.  Z axis is enabled when the parameter value is 1.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
ZoomSpeed8500,114.9.0 and later 

The key is used in order to set the zoom step when panasonic-850 telemetry protocol is in use:

1 – zooming with 50% step of max. possible

0 – zooming with 20% step of max. possible

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
Zdirection0, 104.7.6

The key is responsible for coordinate move in the Z-direction.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
Ydirection0, 104.7.6

The key is responsible for coordinate move in the Y-direction.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
Xdirection0, 104.7.6

The key is responsible for coordinate move in the X-direction.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
WaitDelay>=004.7.5If a joystick sends the messages about its state to Intellect too frequently and Intellect has no time to process these messages, then this parameter is in use – it allows calling the signal handler less frequently. For instance, this parameter should be used with Axis 295 joystick. The best parameter value is to be chosen. The value should match the 100 – 300 range.      
x32: (x32)\
TELEMETRY
x64: (x64)\TELEMETRY
TelemetryDirectCommand0, 114.9.8

The key specifies way of  command transmission to telemetry:

1 – telemetry server is connected to video servers and sends commands to devices.

0 – telemetry server sends commands to the Intellect core which send them to devices.

See also description of the MonitorToTelemetryDirectCommand key below.

x32: (x32)\
TELEMETRY
x64: (x64)\TELEMETRY
MonitorToTelemetryDirectCommand0, 104.9.8

The key specifies way of transmission telemetry commands while control from the Monitor:

1 – telemetry server is connected to video servers and sends commands to devices while telemetry control from the Monitor.

0 – telemetry server sends commands to the Intellect core which send them to devices while telemetry control from the Monitor.

The key is in use with the TelemetryDirectCommand key to provide smoother telemetry control. Recommended values of these keys:

TelemetryDirectCommand = 1 (default value)

MonitorToTelemetryDirectCommand = 1 (attention: default value is 0)

Attention! Client, server and camera should be in one subnet without video gate when using these registry keys. Otherwise, system will not operate.
x32: (x32)\
TELEMETRY
x64: (x64)\TELEMETRY
SendEventToCore0, 104.10.0

The key is to enable the function of sending events to Intellect core when controlling PTZ. This function is essential for PTZ control audit.

1 – when sending any reaction of TELEMETRY object the corresponding event is generated.

0 – during PTZ control events are not generated.
x32: (X32)\
Video\CommonPresets
x64: (x64)\Video\CommonPresets
ONVIF0, 104.10.0

The key enables presets created on the camera in Intellect. The function is only available when camera is connected via ONVIF protocol and only if video server settings are selected when adding a Video capture device using the Camera discovery tool and the Use device settings checkbox is set unchecked on the settings panel of the Video Capture Device object.

0 – presets created on the camera are not used in Intellect.

1 – presets created on the camera are in use in Intellect. The features are listed below:

  1. The preset ID on the camera is to be the same as the preset ID in Intellect or differ by 1 depending on the camera features (see item 2).
  2. As preset numeration starts differently on various cameras (with 0 or 1), then preset numbers can differ by 1 in Intellect. If the numeration on the camera starts with 0, then numeration in Intellect is the same. If the numeration on the camera starts with 1, then numeration in Intellect is greater by 1 (for instance, the first preset on the camera corresponds to the second in Intellect and the first in Intellect is not active).
x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
panas850_stop_dublicates>0-4.10.2The key is in use if the camera rotation is not stopped when telemetry is controlled over Panasonic-850 protocol. The key specifies how many times the stop command is to be duplicated. 

TABLE OF CONTENTS

 

Player

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\Player
x64: (x64)\Player

Wav_delay

> = 0

0

 4.7.3 and later 

Defines the sound delay (sec) when playing back synchronously video with the sound.

TABLE OF CONTENTS

 

Event log 

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\ EventViewer
x64: (x64)\EventViewer

Overlay

0, 1

1

4.7.3 and later

Defines whether to use overlay.

x32: (X32)\ EventViewer
x64: (x64)\EventViewer

Topmost

0, 1

0

4.7.3 and later

Defines whether to display event log as topmost window: 

0 - standard window;

1 - topmost window.

x32: (X32)\ EventViewer
x64: (x64)\EventViewer

UserActivityTimeout>034.10.3

It sets the time period in minutes, after which, if there is no user activity, automatic scroll to the end of the event list when new events arrive is enabled in the Event Viewer window.

If 0 is specified, then automatic scroll is disabled.

TABLE OF CONTENTS

 

Disabling system objects 

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\ Subscribe
x64: (x64)\Subscribe

OBJECT_NAME

(*) (№.*) (№.№)

 

4.7.3 and later

Describes rules for system starting. Unimplemented system objects are disabled.

You should create a string parameter with the name that is used by the system of the object that is to be disabled and specify its ID separated by a full stop.
Example: DEPARTMENT.1:
«0» - disable,
«1» - enable
The “.*” parameter can be used - in this case all objects with “DEPARTMENT” name are disabled. Take into account that parameter with the ID is of a higher priority than the “.*” parameter. So there is no need to describe all objects by listing their IDs if there are a lot of objects that are to be disabled. You can just set 0 value to the “.*” parameter and list the objects that are not to be disabled.
All values are to be written in capital letters.
This registry section is applied to all system objects.

TABLE OF CONTENTS

 

IP integration (drivers and codecs pack for Intellect)

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\Video
x64: (x64)\Video

ArchiveFps

1-24

 

4.7.5 and later

Sets the number of frames recorded to the archive (max.resolution). LiveFps and ArchiveFps parameters are not to exceed 24 in total.

x32: (X32)\Video
x64: (x64)\Video

ArecontVision

0, 1

 

up to  4.8.0

Enables the protocol for integrating Arecont cameras. The key is not in use.

x32: (X32)\Video
x64: (x64)\Video

DoubleStream

0, 1

 

4.7.5 and later

Defines whether asynchronous video display mode is enabled or not.

x32: (X32)\Video
x64: (x64)\Video

IpIntDrivers3

Brand name: Axis; Acti, etc.

 

4.7.3 and later

The IpIntDrivers3 string parameter is created and the names of brands that need 3.0 driver are listed.

x32: (X32)\Video
x64: (x64)\Video

IpIntDriverVersion

2, 3

 

4.7.3 and later

Defines the version number of loaded drivers:
2 – to load drivers version 2.0;
3 - to load drivers version 3.0;
This parameter has a high priority and cancels IpIntDrivers3 parameter.

x32: (X32)\Video
x64: (x64)\Video

LiveFps

1-24

 

4.7.5 and later

Sets the number of frames displayed in the 800x600 format. LiveFps and ArchiveFps parameters are not to exceed 24 in total.

x32: (X32)
x64: (x64)

LoadIpIntDirectly

0, 1

 

4.9.0 and later 

1 - enable IntegratedDevice via video.run. If the setting is enabled and at least one IntegratedDevice is added, then other IP video capture cards are disabled.

0 - IIntegratedDevice operates as a separate run-module.

x32: (X32)\Video\TransportProtocols
x64: (x64)\Video\TransportProtocols
<Driver name><protocol>-DP 3.1.1 and later

The key is used to change a transport protocol used by the IP device.

Example of the key value: "ONVIF"="tcp" means that TCP protocol is used to transfer data via ONVIF.

See details in Changing the transport protocol used by IP-device

Example of the key value: "rtsp"="multicast" allows enabling Multicast mode of the RTSP Server. The object configuration is required in addition to the key.

See details in Configuring RTSP Server module.

x32: (X32)\Video\MetadataTransportProtocols
x64: (x64)\Video\MetadataTransportProtocols

The name of camera driver (in the driver parameter of the

C:\Program Files\ Common Files\ AxxonSoft\ Ipint.DriverPack \3.0.0\ Ipint.<Driver name>.rep file)
The name of transport protocol (is to be the same as one of the values specified in metadataTransportProtocol property in the corresponding .rep file).-DP 3.31.1613 and laterThe key is used to change a metadata transport protocol. At the time of writing this documentation change of a metadata transport protocol was available for ONVIF driver only (possible values are tcp and udp).
x32: (X32)\Video
x64: (x64)\Video
UnloadUnusedDriverTimeout>=060DP 3.32.1638 and later

The key sets unused driver unload timeout for cameras. For instance, if camera brand is in several drivers, all of them are loaded at camera connection. To unload the unused drivers, set non-zero value to this key.

If the key is not created, then unused drivers are unloaded in 60 seconds.

0 – drivers do not unload (such behavior was in DriverPack versions older than the current one).

The key value that is > 0 sets unused driver unload timeout.

If the key is created but it consists of NaN value, then unused driver unload timeout is set to the default value – 60 seconds.

x32: (X32)\TELEMETRY
x64: (x64)\TELEMETRY

PresetCompatibility0, 1-DP 3.43.1950 and later

The key is used to enable the compatibility between presets in Intellect and previous versions of Drivers Pack, i.e. to decreasing the preset number by 1 when sending it to the driver.

0 – a new operation mechanism with presets the same as in AxxonNext is in use in Intellect. If preset 1 is selected in Intellect interface, then value 1 is sent to the driver.

1, or if the key is not created – the compatibility mode is in use: if preset 1 is selected/created in Intellect interface, then value 0 is sent to the driver.

x32: (x32)\Video
x64: (x64)\Video

FFTHREADCOUNT>=01DP 3.43.1955 and later

The key sets the number of streams created in FFmpegDecoder.

0 – decoder automatically selects the number of created streams.

>0 – sets the number of streams in use.

By default if there is no key or the value is incorrect, then value 1 is in use.

Auto selection of the number of streams can result in the system load reduction or its increase as the number of streams recreated during decoding increases – this affects the performance.

x32: (x32)\EventSources
x64: (x64)\EventSources

<brand>.<model> (for example, ONVIF.1_channel_device).

If all models of some manufacturer require a specific method of getting events, then there must be a string key named <brand> in the section.

Pull point

Meta data

Disable

Meta dataDP 3.35.1692

By the date the documentation in created, this key is supported for three brands: ONVIF, RVi and IDIS. For models of these brands, the key is created automatically when the Drivers Pack is installed.

The key sets a method of getting data about the analytics and the sensors of the device:

  • Pull point – getting events by http request of the camera
  • Meta data – getting events from the metadata stream
  • Disable – getting events is disabled.
All other values (including an empty string) or if there is no key for the model and brand in the specified section mean that you must use the default method, created as default in the rep file for the given model.
x32: (x32)\Video\UseSsrcChecking
x64: (x64)\Video\UseSsrcChecking
RTSP

enable

disable

enableDP 3.45.2055

The key is intended for setting up synchronization source (SSRC) for RTSP stream:

enable – SSRC check enabled;

disable – SSRC ched disabled.

x32: (x32)\Video
x64: (x64)\Video

FFLOGDELAY0, 10CP 1.580Enables logging of delays of frames decoding and idle time for FFMPEG codec.
х32: (x32)\Video\TsConverters
x64: (x64)\Video\TsConverters

<brand>.<model>, for example, Tattile.ANPR Mobile

If all brand's models require a certain method of the timestamp adjustment, then the section must contain a string key with the name <brand>.

  • InfrequentTs
  • ValidDeviceTs
  • None
Depends on the brandDP 3.34 and later

The keys in this section specify the method of the frame timestamp adjustment.

If the key is not created, the timestamp transferred to the Intellect equals 0, and then the current time is set as its value.

The None value is used if it is necessary to disable the adjustment and transfer the timestamp received from the camera as is.

The ValidDeviceTs value means that the timestamp adjustment method is used before the timestamps transmission to the Intellect if the timestamp received from the camera differs from the current time by the value greater than the one specified in the MaxTimestampDeviation key (see below). After the adjustment, the timestamp calculated on the basis of the previous frame's timestamp and the time elapsed since its reception is transmitted to the Intellect.

InfrequentTs value discards the relative timestamps, transferring 0 to the Intellect instead (i.e., the current time is set as the timestamp value), and it also transfers the absolute timestamps with the ETimestampValidityFlag flag. This adjustment method should be used for the devices with the license plates recognition which transfer the separate frames to the external system, rather than a continuous video stream.

For some manufacturers, when installing the Drivers Pack, the keys with the necessary values are automatically created in the appropriate registry key.

х32: (x32)\Video
x64: (x64)\Video
MaxTimestampDeviation>=0-DP 3.34 and later

The key is used for the ValidDeviceTs key value from the TsConverters branch (see above).

The key sets the maximum permissible deviation of the frame timestamp from the current Server time.

x32: (x32)\Video
x64: (x64)\Video
ErrorSensitivity0, 10DP 3.54 and later

The key enables the interruption of the H.265 video decoding via the ffmpeg decoder in case of the slightest error in the video stream.

0 - if the video stream contains errors, then a buffer with artifacts will be received from the ffmpeg decoder.

1 - if the video stream contains errors, then an empty buffer will be received from the ffmpeg decoder.

TABLE OF CONTENTS

 

Import module 

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\ DB Import
x64: (x64)\ DB Import

ChunkSize

> 0 and >= photo size

32768

4.7.3 and later

Sets the buffer size (in bytes) when reading large files (photo) in the external DB.

x32: (X32)\ DB Import
x64: (x64)\ DB Import

CursorLocation

1, 2, 3

2

4.7.3 and later

Sets the cursor location (pointer to DB entries):
1 – do not create the cursor;
2 – create the cursor on the Server;
3 – create the cursor on the Client.

x32: (X32)\ DB Import
x64: (x64)\ DB Import

DwSleep

> = 0

1

4.7.3 and later

Sets the delay value (ms) when sending modified entries to the core in the external DB in order not to get 100% CPU load.

x32: (X32)\ DB Import
x64: (x64)\ DB Import

FlagsLog

-

-

up to 4.7.5

 

x32: (X32)\ DB Import
x64: (x64)\ DB Import

MoveFirst

0

0

4.7.3 and later

The key must not be modified.

x32: (X32)\ events
x64: (x64)\ events

Events_out

-

-

up to 4.7.5

Debug key

x32: (X32)\ events
x64: (x64)\ events

Events_out2

-

-

up to 4.7.5

Debug key

x32: (X32)\ events
x64: (x64)\ events

In

-

-

up to 4.7.5

Debug key

x32: (X32)\ events
x64: (x64)\ events

PostedEvents

-

-

up to 4.7.5

Debug key

x32: (X32)\ events
x64: (x64)\ events

PostedReacts

-

-

up to 4.7.5

Debug key

x32: (X32)\ events
x64: (x64)\ events

Reacts_out

-

-

up to 4.7.5

Debug key

TABLE OF CONTENTS