Settings panel of the ATM Monitoring reports interface object is given on the figure.
Description of the ATM Monitoring reports object settings panel elements is given in the table.
# | Parameter | Method for setting the parameter value | Description | Type | Default value | Value range |
1 | Identifier | Automatically | Shows the identification number of the ATM Monitoring reports object in the system | Nonnegative integer | - | >=0 |
2 | Parameter | Enter the value in the field | Shows the identification number of the ATM Monitoring reports object in the system | Latin, Cyrillic letters and service characters | Monitoring | A line representing a sequence of any symbols Number of symbols – from 1 to 60.
|
3 | Display | Is selected in the list | Assigns the parent Display object for the ATM Monitoring reports object | Names of Display objects registered in the system | Name of the parent Display object | Depends on the number of the Display objects in the system. |
4 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the ATM Monitoring reports interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
5 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the ATM Monitoring reports interface box | % of the screen height | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
6 | W: | Enter the value in the field | Sets width of he ATM Monitoring reports interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
7 | H: | Enter the value in the field | Sets height of he ATM Monitoring reports interface box | % of the screen height | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
8 | Filter by owners | Via the Filters... button | Displays selected pairs of users and owners | - | - | - |
9 | Filter... | Click the button | Opens a dialog box to match owners to users | - | - | - |
10 | Reports | Set by checkbox | Select reports available in the interface window. Note. Vehicle LPs report is not in use in ATM Intellect. | Boolean | All checkboxes are set, full access to the Vehicle PLs report is set | Yes – the report button is displayed in the Monitoring Reports interface window. No – the report button is not displayed in the Monitoring Reports interface window. |