The KeyWatcher ACS hardware setup in ACFA Intellect is performed on the KeyWatcher ACS object setup panel. This object is created on the base of Computer object on the Hardware tab of the System settings dialog box.
The KeyWatcher ACS hardware setup is performed in the following sequence:
Enter the number of COM-Port, to which the KeyWatcher ACS hardware is connected, in the corresponding field by clicking up-and-down buttons (1).
In case if the hardware connection is performed by Ethernet interface one should specify the COM-Port virtual number created by Protocol Converter. |
Enter the user’s PIN-code in the corresponding field to get KeyWatcher ACS hardware access (3).
See the user identificator and PIN-code by default in the vendor’s documentation. |
When the KeyWatcher ACS hardware is connected and ACFA Intellect is launched, audio signals are constantly arriving from the hardware. That means ACFA Intellect requests to the hardware: reads the events and sends commands. |
KeyWatcher ACS hardware setup.