The figure shows the POS-terminal object settings panel.
The table describes the elements in the POS-terminal settings panel
No | Element name | Element type | Description | Data type | Default value | Value range |
1 | Number | Auto | Identification number of the object in the system | Whole positive numbers | - | Depends on the number of existing POS-terminal objects |
2 | Name | Text field | Object name | Latin, Cyrillic and special symbols | POS-terminal | Case-insensitive string of any symbols No more than 60 symbols |
3 | Disable | Checkbox | Object status | Boolean | No | Yes – the object is disabled (not used) No – the object is enabled |
4 | Computer | Drop-down list | Parent Computer object | Names of existing Computer objects | Parent computer name | Depends on the number of existing Computer objects |
The Recording modes group | ||||||
5 | Recording mode | Drop-down list | The recording mode | Existing recording modes | Record on receipt beginning/end | Record on receipt beginning/end Continuous recording Save one frame per receipt |
Post-recording interval | Text field | Post-recording time interval | Seconds | 30 |
| |
Motion detector | Checkbox | Record on motion detector activation | Boolean | Yes | Yes – use motion detector No – do not use motion detector | |
Receipts only | Checkbox | Receipt display option | Boolean | No | Yes – only data of the receipts between the beginning and end of the receipts are displayed on the screen and included in the Captioner No – all the data of the processed receipts are displayed on the screen and included in the Captioner
| |
The Connection settings group | ||||||
6 | Type | Drop-down list | Connection type | Supported protocols | RS232 | Depends on the number of supported protocols |
Port | Drop-down list | Port number | Available ports | COM1 | Number of available ports | |
Speed | Drop-down list | Connection rate in accordance with RS232 protocol | Supported rates | 9600 | Depends on the number of supported rates in accordance with RS232 protocol | |
Parity | Drop-down list | Parity mode for RS232 protocol | Supported parity modes | None | Depends on the number of supported parity modes in the RS232 protocol | |
DTR | Checkbox | DTR option for RS232 protocol | Boolean | No | Yes – use DTR control signal in the RS232 protocol No – do not use DTR control signal in the RS232 protocol | |
RTS | Checkbox | RTS option for RS232 protocol | Boolean | No | Yes – use RTS control signal in the RS232 protocol No – do not use RTS control signal in the RS232 protocol | |
The Captioner group | ||||||
7 | Available captioners | Auto | The list of available captioners | – | – | – |
Selected captioners | Auto | The list of selected captioners | – | – | – | |
| <, >, >>, << | Button | Selecting the captioners | – | – | – |
8 | Advanced | Button | Opening additional POS-terminal object settings | – | – | – |
9 | Receipts archive depth | Text field | The size of the receipts archive | Days | 30 |
|