Configuring access cards allows you to set the required number and format of user access cards (see Assigning an access card to a user).
Access cards are configured as follows:
from 1 to 5 - if the specified number of access cards is not assigned to the user, then this user cannot be saved in the Access Manager interface object.
Unlimited - an unlimited number of access cards can be assigned to the user.
Prohibited - the user cannot be assigned access cards. Buttons and functional menu for assigning access cards will be inactive in the Access Manager interface object.
from 1 to 5 - if the user is assigned more than the specified number of access cards, then this user cannot be saved in the Access Manager interface object.
Unlimited - an unlimited number of access cards can be assigned to the user.
Prohibited - the user cannot be assigned access cards. Buttons and functional menu for assigning access cards will be inactive in the Access Manager interface object.
|
If the following access cards restrictions are violated, the user cannot be saved in the Access Manager interface object. |
Default - allows setting an arbitrary value for the facility code and card code. Any letters, numbers and symbols are allowed except: <| >.
Wiegand26 - allows entering a 1-byte facility code (from 0 to 255), and a 2-byte card code (from 0 to 65535).
Wiegand32 - allows entering a 2-byte facility code (from 0 to 65535), and a 2-byte card code (from 0 to 65535).
Wiegand26 (code only) - the facility code cannot be set, only a 3-byte card code is set (from 0 to 16777215).
Wiegand32 (code only) - the facility code cannot be set, only a 4-byte card code is set (from 0 to 4294967295).
TouchMemory - the facility code cannot be set, only the 8-byte card code is set. The format is hexadecimal, characters A, B, C, D, E, F are allowed. The code should be 8 characters or longer. If the entered card code is less than 8 characters long, the the higher order digits are filled with zeros.
Hikvision - the Hikvision ACS format. It always has a fixed H character in the facility code. The card code is specified by a string with a maximum length of 32 characters.
Configurable - allows setting the parameters of the facility code (5) and card code (6).
Fixed character - the specified single character will always be hard-coded, which cannot be changed in the Access Manager interface object.
String - allows entering a string of 0 to 255 characters.
Numeric - allows entering only numbers from 0 to 4294967295.
Hexadecimal - allows entering numbers in HEX format (numbers and symbols A, B, C, D, E, F) from 0 to 8 bytes long.
Fixed number - similar to Fixed character, but instead of a character, a number between 0 and 4294967295 is used.
Regular template - allows defining an access card template with specified restrictions, lengths and value ranges.
An example of some service characters for regular expressions:
On the site https://regex101.com you can find a complete list of service characters for regular expressions, as well as to check the accuracy of a regular expression. |
Example 1:
For the facility code, it is necessary to limit the range of entered numbers from 1 to 3. The amount of numbers should be not more than 4. Other characters and numbers are not allowed.
Template:
^[1-3]{4}$ |
Example 2:
For a card code, it is necessary to limit the code length to 8 characters, at least 1 character for input. In this case, it is allowed to enter uppercase Latin letters A, B, C, D, E, F.
Template:
^[(A-F),(0-9)]{1,8}$ |
Configuring access cards is complete.