For remote systems, it is possible to receive events from the LPR channel. The Server with the running Auto-Intellect software acts as a TCP Server.
When a new LP number is added to the Auto-Intellect database, the Server transfers the data via the TCP port 35555 and TCP port 55555 in the following formats:
<?xml version="1.0" encoding="UTF-8"?><CAR_PLATE version="1.0" direction = "in" cam-id = "4" time = "2020-07-21T18:37:44.695" plate = "x000xx000" plate_mask = "" confidence = "99" plateImage = "imagebase64" >..imagebase64..</CAR_PLATE> |
The transmitted data structure is described in the table below.
Name | Description |
---|---|
direction | Vehicle moving direction. The following values are possible:
|
cam-id | ID of the camera that captured the vehicle |
time | Time of LP number recognition |
plate | If the LP number was recognized, the field contains the text of the recognized number, otherwise - "Not defined" |
plate_mask | Country the recognized LP number belongs to |
confidence | Accuracy of LP number recognition in percent |
plateImage | License plate image in "base64" format |
> ..imagebase64.. < | Vehicle image in "base64" format |
0x02YYYYMMDDHHMMSSCCNNNNNNNNN0x03 |
The transmitted data structure is described in the table below.
Name | Description |
---|---|
0x02 | Start byte |
YYYY | Year (four numbers 0000-9999) |
MM | Month (two numbers 01-12) |
DD | Day of the month (two numbers 01-31) |
HH | Hour (two numbers 00-23) |
MM | Minutes (two numbers 00-59) |
SS | Seconds (two numbers 00-59) |
CC | Camera number (two numbers 00-99) |
NNNNNNNNN | Text of the recognized number (arbitrary number of symbols), or "Not defined" if the number was not recognized |
0x03 | End byte |
The beginning and end of the message are transferred by the start byte and the end byte respectively. The message between these bytes is transferred in text format. |