The settings panel of the SIP-panel object is shown in the figure.

The description of the SIP-panel interface object settings is shown in the table.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
The Filters tab

1

The Identification number field

Automatically

Shows the identification number of the SIP-panel object in the system

Positive integer

-

Depends on the number of SIP-panel objects in the system

2

The Name field

Type-in the value in the field

Assigns the name to the SIP-panel object

Latin, Cyrillic and service characters

Display manager

A line containing a sequence of any symbols (letters, digits, service, characters apart from > and < symbols), non case-sensitive

Number of symbols – from 1 to 60

3

The Disable checkbox

Set the chechbox

Shows the status (enabled or disabled) of the SIP-panel object in the system


Boolean type

No

Yes – the SIP-panel object is disabled and is not in use

No – the SIP-panel object is enabled and is in use

4

The Display dropdown list

Select from the list

Assigns the parent Display object, to which the given SIP-panel object refers

Name of the Display objects registered in the system

Name of the parent Display object

Depends on the number of the Display objects in the system

5


The X filed

Type-in the value in the field

Sets the coordinate in the X horizontal axis for the upper left corner of the SIP-panel interface object on the screen

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The Y field

Type-in the value in the field

Sets the coordinate in the Y vertical axis for the upper left corner of the SIP-panel interface object on the screen

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

6


The W filed

Type-in the value in the field

Sets the window width of the SIP-panel interface object

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The H field

Type-in the value in the field

Sets the window height of the SIP-panel interface object

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

7The Monitor dropdown listSelect in the listSets the system ID of the monitor for which the coordinates are setIDs of the monitors in the OS1From 1 to 16

8

The Display only when calling checkbox

Chechbox is set

Enables displaying of the SIP-panel interface box only at call

Boolean type

No

Yesthe SIP panel is only displayed during call.

Nothe SIP panel is always displayed.

9The Terminal drop-down listSelect in the listSets the SIP-terminal object which SIP-devices use the SIP Panel.Name of the SIP Panel objects registered in the system-Depends on the number of the SIP Panel objects in the system
10The Monitor drop-downSelect in the listSets the the Monitor object corresponding to the Video Surveillance Monitor to which the video cameras associated with the corresponding SIP-devices are added.Name of the Monitor objects registered in the system-Depends on the number of the Monitor objects in the system
11The Camera drop-down listSelect in the listSets the operator's camera, the video image from which should be transmitted when calling from/to the Intellect SIP-terminal via the SIP Panel.Name of the Camera objects registered in the system-Depends on the number of the Camera objects in the system
12The Microphone drop-down list Select in the listSets the operator's microphone, the sound from which should be transmitted when calling from/to the Intellect SIP-terminal via the SIP Panel.Name of the Microphone objects registered in the system-Depends on the number of the Microphone objects in the system

13