The settings panel of the SIP-device object is shown in the pictures below.

Table describes the parameters of the SIP-device settings panel.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1

The Identification number field

Automatically

Shows the identification number of the

SIP-device object in the system.

Sequence of numbers

-

Depends on the number of the SIP-device objects in the system.

2

The Name field

Enter the value in the field

Assigns a name to the SIP-device object in the system.

Latin, Cyrillic letters and service characters

SIP-device

A line representing a sequence of any symbols

(letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

The Disable checkbox

Is set with a checkbox

Shows the status (enabled or disabled) of the SIP-device object in the system.

Boolean type

-

Yes – the SIP-device object is disabled and is not in use.

No – the SIP-device object is enabled and is in use.

4

The SIP-terminal dropdown list

Is selected in the list

Assigns the parent SIP-terminal object for the SIP-device object.

Name of the SIP-terminal objects

registered in the system.

Name of the parent

SIP-terminal object

Depends on the number of the SIP-terminal objects in the system.

5The Device type drop-down listIs selected in the listSets the icon type to represent the device on the Map.Names of the available icon types-

SIP client — the SIP-device acts as a client, it can be connected to any SIP-server

SIP server — the SIP-device acts as a server, any SIP-clients can be connected to it

Peer-to-peer terminal type is not supported at the present moment.

The Connection settins group

6The User ID fieldEnter the value in the fieldSets the SIP-device identification number, i.e. the number to call it.Integer
>=0
7The IP address fieldEnter the value in the field

For SIP-server terminal type only

Sets the SIP-device IP address.

IP address
1.0.0.0 - 255.255.255.255
8The Password fieldEnter the value in the field

For SIP-server terminal type only

Sets the password specified on the SIP-device.

Latin, Cyrillic letters and service characters
A line representing a sequence of any symbols
9The State fieldAutomatically

For SIP-server terminal type only

Displays the SIP device state

---
The Video/Audio tab (for SIP-server terminal type only)
10The Video switchSet the switch to the required positionSets the video camera used for callsSupported options of camera usageOff

Off — the video is not used during the call.

SIP camera — a SIP-device camera connected via the SIP protocol is used.

Other — any other camera from the Intellect hardware tree selected from the Camera drop-down list is used.

11The Camera drop-down listIs selected in the listSets any video camera used for calls

Name of the Camera objects

registered in the system.

-Depends on the number of the Camers objects in the system.
12The Audio switchSet the switch to the required positionSets the microphone used for callsSupported options of audio usageOff

Off — the audio is not used during the call.

On — the microphone of the SIP-device is used.

13The Microphone fieldAutomaticallyDisplays the name of the Microphone object corresponding to the SIP device---
The Relay tab (for SIP-server terminal type only)
14The DTMF type drop-down listIs selected in the listSets the type of the tone DTMF commandSupported signal typein_bound

in_band – the signal is transmitted as normal sound in an audio stream.

rtp_nte – signals are transmitted via RTP separately from the voice stream.

sip_info – signals are transmitted in the SIP INFO message.

sip_notify – signals are transmitted in the SIP NOTIFY message.

15The Signal duration, ms fieldEnter the value in the fieldSets the time period in milliseconds during which the command is to be sent.Integer
>0
16The Name fieldEnter the value in the fieldSets the name of the command displayed on the SIP panel Latin, Cyrillic letters and service characters
A line representing a sequence of any symbols
17The Code fieldEnter the value in the fieldSets the unique command codeInteger
>0