The PTZ object is displayed in the objects tree as the child object to the camera, if it is the PTZ camera.
To configure the PTZ device of the camera, do the following:
Select the Home preset by specifying the required identifier (5). The home preset will return automatically after the time period specified in the Home preset timeout field (6).
If the Home preset timeout value is greater than the Operator idle time value (see Configuring PTZ control), the Operator idle time value will be used. |
To simultaneously control the PTZ camera by multiple users with the same priority, select Yes in the Multiple control list (7). Otherwise, only one user at a time will have a control (see Controlling a PTZ Camera).
To use the existing presets on the device in Axxon Next, do the following:
Create the presets with identical IDs in Axxon Next (see Creating and editing presets).
If the use of the existing presets is disabled, they can be lost if the following conditions are met: 1. The recording of the presets to the device is enabled in Axxon Next (see point 9). 2. The preset with the same ID is created in Axxon Next (see Creating and editing presets). |
Select the default patrol mode: Yes — on, No — off (9). If patrolling is enabled by default, it can be stopped in PTZ control panel (see Patrolling). After you finish the PTZ control session, patrolling will resume automatically.
By default, the presets are recorded in the IP device. If you want to store the presets on the Server only, select No for the Save presets parameter (11).
This parameter is available only for the devices that support Absolute Positioning. |
If necessary, configure the Tag & Track function (14, see Configuring Tag&Track Pro).
Depending on the camera, you may find other parameters in the Other group (15). To configure them, refer to their description in the interface or in the official documentation.
As a result, the PTZ device will switch to the specified operating mode.
To check the operation of the PTZ device, click the button. If the PTZ device is configured correctly, it will turn one step and return to its original position.