To configure the face temperature monitoring and control, do the following:

  1. Configure Face-Intellect according to the documentation.

    Configuring the Face Recognition Server operation with thermal camera


  2. Configure the FACE access point object according to the documentation. The required settings are shown below:

  3. Configure the Event manager module according to the documentation. The required settings are shown below:
    1. Create and configure the Rule of displaying object for each monitoring/control mode:
      • For the Type of object parameter, select FACE access point.
      • For the Template parameter, select a display template for the temperature monitoring or control, respectively (see step 3.b).
      • On the Objects tab, select the appropriate FACE access point object for the temperature monitoring or control.
      • On the Events tab, if the Rule of displaying object is configured for the temperature monitoring, set the checkbox for the Face recognized (temperature log) event. If the Rule of displaying object is configured for the temperature control, then set the checkbox for the Face with fever recognized event.
    2. Create and configure the Template of displaying object for each monitoring/control mode:

      Database field оbject properties

      1. To display the name of the event for which the Event manager is configured, add the Database field object and specify the following value in the Unusual parameter:

        rule_service_action_name


      2. To display the full name, add several Database field objects and specify the value from the database (First name, Surname, Patronymic) in the Predefined field, or add only one Database field object, and specify the following value in the Unusual parameter:

        {param0}


      3. To display the date and time when the face and temperature were recognized, add the Database field object and specify the following value in the Unusual parameter:

        {date} {time}


      4. To display the temperature received from the thermal camera, add the Database field object and specify the following value in the Unusual parameter:

        {temperature}


        For example, for a temperature control template, you can specify the following in the Unusual parameter:

        Attention! High temperature: {temperature} °C {\n} The door is locked.



      5. The examples of display templates are shown below.

        Display template for the temperature monitoringDisplay template for the temperature control


The example of a configured system for the temperature monitoring and control:

  1. Temperature monitoring mode:

  2. Temperature control mode: