The visitor counter is better fit for producing average figures than exact values. |
We cannot guarantee correct operation of the visitors counter with fish-eye video cameras. |
To configure the visitors counter:
By default, the frame is compressed to 1920 pixels on the longer side. To avoid detection errors on streams with a higher resolution, it is recommended that compression be reduced (3).
By default, the detection tool outputs the Camera. Visitor access in the direction of "Entrance" and Camera. Visitor access in the direction of "Exit" events. If total footfall and visitor number control / exceeding notification is required, do the following:
Select Yes for the People indoor counter parameter (5).
Enter the current number of visitors within the area (4).
Set the threshold value for the visitor counter; exceeding this limit will generate the corresponding event (6).
In the Preview window, set the detection area. It is divided to two sectors, #1 and #2. When an object moves from #2 to #1, the system treats it as entry; alternatively, #1 to #2 is treated as exit.
To configure the sectors, you can drag them by corners or sides.
To swap sectors, just click inside one of them.
To show / hide sectors in the Preview window, click the |
Configuration of the visitors counter is now complete.