The Equipment detection (PPE) module is configured on the settings panel of the Equipment detection (PPE) object created on the basis of the Camera object on the Hardware tab of the System settings dialog window.
The Equipment detection (PPE) module is configured as follows:
In the Sensitivity, % field (1), enter the detector sensitivity - an integer value from 0 to 100.
The detector sensitivity is determined experimentally. The lower the sensitivity, the greater the probability of false positives. The higher the sensitivity, the less chance of false alarms, however, some useful tracks may be skipped. |
In the Interval between the analyzed frames (ms) field (4), enter the interval between the analyzed frames in milliseconds. The value should be in the [30; 10000] range.
In the Number of frames for analysis and output field (5), enter the minimum number of frames on which a violation should be detected in order to generate a trigger. The value should be in the [2; 20] range.
By default, the detection triggering for each item of equipment will be generated once within one track of a person. If it is necessary to generate a trigger for each equipment violation, then set the One event per equipment element checkbox (6).
Example. A person appeared in the frame without a helmet, then put it on and then took it off again. If the One event per equipment element checkbox is set, then there will be one trigger, if not - two. |
From the Working mode drop-down list (8) select the device on which the neural network will operate.
Click the Setup button (9). The Detection settings window will open.
The Equipment detection (PPE) module is now configured.