The Neurocounter module can be configured on the settings panel of the Neurocounter object created on the basis of the Camera object on the Hardware tab of the System settings dialog window.
The Neurocounter module is configured as follows:
In the Interval between processed frames field (2), specify the time interval in seconds between the analyzed frames. This parameter is related to the Number of processed frames parameter.
The default values (Number of processed frames: 3 frames and Interval between processed frames: 1 second) mean that the neural counter will analyze 3 frames, one frame per second. After processing 3 frames, depending on the condition of the event generation, either an event with the number of detected objects will be generated, or processing of the next 3 frames will start. |
In the Sensitivity, % field (6), enter the neural counter sensitivity – integer value from 0 to 100.
The neural counter sensitivity is determined experimentally. The lower the sensitivity, the more false triggerings there might be. The higher the sensitivity, the less false triggerings there might be, however, some useful tracks might be skipped. |
Configuring the Neurocounter module is complete.