Installation of Central Server of Control software is performed in the following sequence:
A dialog box to configure database connection will be displayed. Select the database server name and set up the connection parameters. Click Next.
In the Select database Server from the drop-down list field specify the 127.0.0.1 value instead of computer name or "(local)" value. Otherwise Central Server of Control will lose connection with its local database when the network cable is disconnected. |
In the Database field specify the name of the database or select it in the list of databases, which are created in the server, and click <<. Click Next.
By default, the name of the database is "ServerSSTV" and its files will be stored in the SQL Server folder. |
Installation of Central Server of Control software is complete.