The functions of the internal variable determine the actions to be taken when the corresponding logical condition is fulfilled. Up to 6 IV functions can be set, while an IV function can start other IV function.
The IV functions are configured as follows:
Click ... and configure the function parameters (2, see table).
Function | Description | Parameters |
AIO output control | Switch relay on AIO security panel | Security panel Panel relay |
Reader relay control | Switch relay of a reader connected to an AIM controller | AIM controller Reader |
APB Area control | Change APB area state | APB Area |
Create IV call log | Logging a message about fulfillment of conditions of the internal variable | - |
Unlock/select reader mode | Setting operation mode of a reader connected to an AIM controller | AIM controller Reader type |
Call of other IV functions | Performing functions of another internal variable, regardless of the meaning of its terms | Variable |
Shift of masking level of zone group | Increment masking level by 1 for each IV's term, if the term is TRUE | Zone group |
Check zone activity in zone group | The term is set to FALSE (0) if there are active zones in the group | Zone group |
Check masking level of zone group | The term is set to 1, if masking level = 0. The term is set to 0 if masking level != 0 | Zone group |
Switch masking level of zone group | Change masking level from 0 to 1 or from 1 to 0, i.e. trigger mode. | Zone group |
Configuring IV functions is completed.