It is possible to configure triggering of executive devices of BioSmart 4 controller when events appear in the system. For this do the following:
- Click the IO button on the settings panel of the BioSmart 4 object.

- In the IO parameters list select the executive device the reaction is to be set to (1).

- Use the >> button in order to forward events that trigger the executive device from the Forbidden events list to the Allowed events list (2).
- In the Delay field specify time (in milliseconds) that is to pass after receiving the selected event until the executive device becomes active (3).
- In the Repetitions field specify the number of the executive device triggerings after receiving the selected event (4).
- In the Active state delay field specify time (in milliseconds) for which the executive device is to become active (5).
- In the Inactive state delay (ms) field specify time (in milliseconds) between triggerings of executive device when there are repetitions (6).
- Repeat steps 2-7 for all required types of executive devices.
- Click the Save and then the Apply button.
Operating scenarios for executive devices of BioSmart 4 controller are now configured.