Configure the Hikvision DS-1200KI PTZ control device as follows before creating the corresponding object in Axxon One:
Set the Axxon One server IP address and port on the device. Open the device Web interface by entering the above set IP address in the web browser, then select Platform Access − Third-Party Platform.
The Web interface is only available on https by default, so please use https prefix before the IP address. |
Select any monitor MON (monitor) [integer in the range 1-9999] and any group of cameras CAM-G (camera group) [integer in the range 1-999999]; in this mode, only the MULT, OK keys and the rotations of the joystick axes will work.
To select these parameters, enter a number on the device keypad, then press the corresponding key (MON/WIN/CAM/CAM-G). If the the server IP address and/or port is not accessible from the PTZ control device, the "Connect failed" message will be displayed on the control device screen after pressing the MON/WIN/CAM/CAM-G keys. |
The Hikvision DS-1200KI PTZ control device is now preconfigured.
When the MULT, PRESET, PATROL, or PATTERN keys are pressed on the device, the following actions are performed: