Video stream and scene requirements for Equipment detection tool (PPE) operation Objects image requirements for Equipment detection tool (PPE) |
To configure the Equipment detection tool (PPE), do the following:
If the camera supports multistreaming, select the stream for which detection is needed (3).
By default, the following neural networks are used according to the selected processing device (9): Classification neural network (head) and Classification neural network (body). To initialize only one item of equipment, select the required classification neural network file (4). There should be a separate classification neural network to recognize equipment on each body segment. The following classification neural networks for different processor types are located in the C:\Program Files\Common Files\AxxonSoft\DetectorPack\NeuroSDK directory:
ppeHelmet(head)General_movidius.ann | Classification neural network (head) / IntelNCS |
ppeHelmet(head)General_openvino.ann | Classification neural network (head) / CPU |
ppeHelmet(head)General_origin.ann | Classification neural network (head) / GPU |
ppeSafetyVest(body)General_movidius.ann | Classification neural network (body) / IntelNCS |
ppeSafetyVest(body)General_openvino.ann | Classification neural network (body) / CPU |
ppeSafetyVest(body)General_origin.ann | Classification neural network (body) / GPU |
If you use a custom neural network, it is necessary to specify the path to the file (3).
To ensure the correct operation of the neural network on Linux OS, the corresponding file should be located in the /opt/AxxonSoft/DetectorPack/NeuroSDK directory. |
Set the frame rate value for the detection tool to process per second (6). This value should be in the range [0,016; 100].
To apply detection in gateway mode (see Examples of configuring Equipment detection tool (PPE) for solving typical tasks), we recommend that you use the detection tool standard settings: 1 fps and 3 frames for output (see i.10). To apply detection in continuous mode for busy scenes, set the delay to no less than 4 FPS, and the number of frames for output to no less than 6. |
Select the processor for the neural network − CPU, one of GPUs, or Intel processors (9, see Hardware requirements for neural analytics operation).
If you specify other processing resource than the CPU, this device will carry the most of computing load. However, the CPU will also be used to run the detection tool. If you have Intel HDDL selected, it can process only the segmenting neural networks. The CPU will process the classifying networks. |
It may take several minutes to launch the algorithm on NVIDIA GPU after you apply the settings. You can use caching to speed up future launches (see Configuring the acceleration of GPU-based neuroanalytics). |
By default, the Segmenting neural network (head, body) is used according to the selected processing device (9). The following segmenting neural networks for different processor types are located in the C:\Program Files\Common Files\AxxonSoft\DetectorPack\NeuroSDK directory:
ppeSegmentationByPose_movidius.ann | Segmenting neural network (head, body) / IntelNCS |
ppeSegmentationByPose_openvino.ann | Segmenting neural network (head, body) / CPU |
ppeSegmentationByPose_origin_onnx.ann | Segmenting neural network (head, body) / GPU |
If you use a custom neural network, it is necessary to specify the path to the file (10).
To ensure the correct operation of the neural network in Linux OS, the corresponding file should be located in the /opt/AxxonSoft/DetectorPack/NeuroSDK directory. |
By default, each equipment element triggering occurs once during a continuous tracking of a person. You can set triggering to multiple by setting the One event per PPE element parameter to No (13).
Example. An individual not wearing a helmet appears in the FOV, puts on a helmet, then puts it off. If the One event per PPE element parameter is enabled, you will have one alarm event, otherwise two. |
The Equipment detection tool (PPE) is now configured.
The Equipment detection tool (PPE) triggers an alarm when a person not wearing required equipment (PPE) on specified body parts, or wearing inappropriate equipment, appears in the FOV.
The Equipment detection tool (PPE) recognizes equipment of the following colors:
To ensure the correct reception of the E-mail notifications (see E-mail notification) after the Equipment detection tool (PPE) is triggered, it is necessary to set up a separate macro command with an E-mail message for each item of equipment. |