To limit access for Operator to playback the Backup archive, do the following:
Specify the number of hours for viewing in the Depth ___ last hours field (3).
The number of last video archive hours for viewing should be whole. |
Input the 0 value in the Depth ___ last hours field to disable access to the Backup archive. |
If the hours since the last entrance to the system are counted, set the Since last access checkbox (4). If the hours are to be counted since the current moment, then leave the Since last access checkbox clear.
If the Since last access checkbox is set and the number of hours for viewing is specified, then last hours are counted till the registration moment. |
If the Since last access checkbox is set, but the Depth ___ last hours field is left blank, the access to the Backup archive playback is not limited. |
The access to Backup archive playback is now limited.