Recommendation on how to choose the installation type:
Server and Client | Failover Server and Client |
---|---|
Choose this type of installation if you have no more than 5 Servers in one location, which should operate within the same Axxon-domain. | Choose this type of installation if you have 5 to 30 Servers (minimum 3) in one location, which should operate within the same Axxon-domain. |
If you have more than 30 Servers in one location, or if they are spread between different locations, but you need to have unified user management across all Servers, please contact your manager or technical support for consulting.
It is highly recommended to install it on SSD specifically designed for storing metadata.
on system drive because Metadata size tends to grow over time, and if the system drive space is not sufficient it might cause system issues. |
Add the following processes to the exclusion list:
Multistreaming:
Set different high and low quality streams for each video camera.
Recommended type : VBR.
Set maximum bitrate/bandwidth values.
Recommended bitrate: 1 Mbps per 1 MP.
May differ for different camera models. |
Make sure pre-recording is enabled (> 1 sec).
Note that after you re-create the archive, it is necessary to re-create all recording rules in the detection tool settings or Programming settings.
To restore the configuration, use the backup created on the same version of software (see Restoring a configuration). Example: if backup was created on v. 1.0 then restore it only on v. 1.0.
Average response time is lower than 1 sec.