The Suprema 2 controller is configured as follows:
From the Region out (9) drop-down list, select the Region corresponding to the area located at side of entrance through the reader.
The Region in and Region out are to be selected if Time&Attendance interface module is in use. Otherwise, leave these fields empty. |
Set the Support Fingerprint (10) check box if the controller supports authorization by fingerprint.
Only set the check boxes for options supported by the Suprema 2 controller. |
Configure sending an event upon successful access: Swap pass/granted (14). If the checkbox is cleared, the Pass event is generated, otherwise, the Access granted event is generated.
The setting is required for the Time and Attendance Module operation with one access terminal. |
Click Apply to save changes (15).