The functions of the internal variable determine the actions to be taken when the corresponding logical condition is fulfilled. Up to six internal variable functions can be set, while an internal variable function can start other internal variable function.
The internal variable functions are configured as follows:
Click ... and configure the function parameters (2, see table).
Function | Description | Parameters |
AIO output control | Switch relay on AIO security panel | Security panel Panel relay |
Reader relay control | Switch relay of a reader connected to an AIM controller | AIM controller Reader |
APB Area control | Change APB area state | APB Area |
Create IV call log | Logging a message about fulfillment of conditions of the internal variable | - |
Unlock/select reader mode | Setting operation mode of a reader connected to an AIM controller | AIM controller Reader type |
Call of other IV functions | Performing functions of another internal variable, regardless of the meaning of its terms | Variable |
Shift of masking level of zone group | Increment masking level by 1 for each IV's term, if the term is TRUE | Zone group |
Check zone activity in zone group | The term is set to FALSE (0) if there are active zones in the group | Zone group |
Check masking level of zone group | The term is set to 1, if masking level = 0. The term is set to 0 if masking level != 0 | Zone group |
Switch masking level of zone group | Change masking level from 0 to 1 or from 1 to 0, i.e. trigger mode. | Zone group |
Configuring IV functions is completed.