Associating AIM input with terms allows changing the value of an internal variable's term at certain events.
Associating AIM input with terms is performed on the settings panel of the Apollo AIM Input object. The object is created on the basis of the Apollo AIM ReaderĀ object.
Associating AIM input with a term is performed as follows:
From the drop-down lists in the Operation with term, if group, select which values the term should have if the AIM input is not configured, armed, in a fault state or in an alarm (3). The following operations are available:
Operation | Description |
No operation | The value of the corresponding term does not change |
Clear term | The term is set to FALSE |
Set term | The term is set to TRUE |
Send impulse | The value of the term changes to the opposite for a short preset period |
Associating AIM input with a term is completed.