The Texecom FSA connection is configured as follows:

  1. Go to the settings panel of the Texecom panel object, which is created on the basis of the Computer object on the Hardware tab of the System Settings dialog box.
  2. From the Connection drop-down list (1), select the panel connection method:
  3. In the Reply timeout, ms field (3), enter the time in milliseconds during which a response is expected from the panel.
  4. In the Reply count field (4), enter the number of attempts to reconnect to the panel in case of communication loss.
  5. From the Panel type drop-down list (5), select the type of panel to be connected.
  6. If the panel is connected using the Premier Elite PC-Com device, then in the UDL Passcode field (6), enter the UDL password or the engineer’s factory code if the UDL password is not programmed.
  7. Click Apply (7) to save the changes.

    If the connection is successful, the protocol version of the data exchange protocol will be displayed in the Protocol version field (8), and the panel type and firmware version on which the panel controller is running will be displayed in the Panel identification field (8).


The Texecom FSA connection is now configured.